An employee's exposure to any substance listed in Table Z-2 shall not exceed the exposure limits specified as follows:
1910.1000(b)(1) 8-Hour Time Weighted Averages
An employee's exposure to any substance listed in Table Z-2, in any 8-hour work shift of a 40-hour work week, shall not exceed the 8-hour time weighted average limit given for that substance in Table Z-2.
1910.1000(b)(2) Acceptable Ceiling Concentrations
An employee's exposure to a substance listed in Table Z-2 shall not exceed at any time during an 8-hour shift the acceptable ceiling concentration limit given for the substance in the table, except for a time period, and up to a concentration not exceeding the maximum duration and concentration allowed in the column under "acceptable maximum peak above the acceptable ceiling concentration for an 8-hour shift."
1910.1000(b)(3) Example
During an 8-hour work shift, an employee may be exposed to a concentration of Substance A (with a 10 ppm TWA, 25 ppm ceiling and 50 ppm peak) above 25 ppm (but never above 50 ppm) only for a maximum period of 10 minutes. Such exposure must be compensated by exposures to concentrations less than 10 ppm so that the cumulative exposure for the entire 8-hour work shift does not exceed a weighted average of 10 ppm.

Related Code Sections

1910.1000(b) Toxic and Hazardous Substances, Table Z-2
An employee's exposure to any substance listed in Table Z-2 shall not exceed the exposure limits specified as follows ...
Subpart Z Toxic and Hazardous Substances
Authority: 29 U.S.C. 653, 655, 657) Secretary of Labor's Order No. 12-71 (36 FR 8754), 8-76 (41 FR 25059), 9-83 (48 FR 35736), 1-90 (55 FR 9033), 6-96 ...
1910.1000(d)(1)(ii) Toxic and Hazardous Substances,
ppm noted in Table Z-1. Assume that an employee is subject to the following exposure: Two hours exposure at 150 ppm Two hours exposure at 75 ppm ...