• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

Section C102 Systems for Flushing Water

2010 Plumbing Code of NY > C Gray Water Recycling Systems > C102 Systems for Flushing Water
JUMP TO FULL CODE CHAPTER

C102.1 Collection Reservoir

The holding capacity of the reservoir shall be a minimum of twice the volume of water required to meet the daily flushing requirements of the fixtures supplied with gray water, but not less than 50 gallons (189 L). The reservoir shall be sized to limit the retention time of gray water to a maximum of 72 hours.

C102.2 Disinfection

Gray water shall be disinfected by an approved method that employs one or more disinfectants such as chlorine, iodine or ozone.

C102.3 Makeup Water

Potable water shall be supplied as a source of makeup water for the gray water system. The potable water supply shall be protected against backflow in accordance with Section 608. There shall be a full-open valve located on the makeup water supply line to the collection reservoir.

C102.4 Coloring

The gray water shall be dyed blue or green with a food grade vegetable dye before such water is supplied to the fixtures.

C102.5 Materials

Distribution piping shall conform to one of the standards listed in Table 605.4.

C102.6 Identification

Distribution piping and reservoirs shall be identified as containing nonpotable water. Piping identification shall be in accordance with Section 608.8.

Related Code Sections


Section C102 Gray Water Recycling Systems, Systems for Flushing Water
The holding capacity of the reservoir shall be a minimum of twice the volume of water required to meet the daily flushing requirements ...
2010 Plumbing Code of NY > C Gray Water Recycling Systems > C102 Systems for Flushing Water
C102.6 Gray Water Recycling Systems, Identification
Distribution piping and reservoirs shall be identified as containing nonpotable water. Piping identification shall be in accordance with Section ...
2010 Plumbing Code of NY > C Gray Water Recycling Systems > C102 Systems for Flushing Water > C102.6 Identification
C101.1 Gray Water Recycling Systems, Scope
The provisions of this appendix shall govern the materials, design, construction and installation of gray water systems for flushing of water closets ...
2010 Plumbing Code of NY > C Gray Water Recycling Systems > C101 General > C101.1 Scope
Section C101 Gray Water Recycling Systems, General
The provisions of this appendix shall govern the materials, design, construction and installation of gray water systems for flushing of water closets ...
2010 Plumbing Code of NY > C Gray Water Recycling Systems > C101 General
C101.4 Gray Water Recycling Systems, Installation
In addition to the provisions of Section C101, systems for flushing of water closets and urinals shall comply with Section C102 and systems ...
2010 Plumbing Code of NY > C Gray Water Recycling Systems > C101 General > C101.4 Installation
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING