• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1910.66(e)(2)(iii)(C) System Utilizing Angulated Roping and Building Face Rollers

OSHA 1910 General Industry > F Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms > 1910.66 Powered Platforms for Building Maintenance > 1910.66(e) Powered Platform Installations-Affected Parts of Buildings > 1910.66(e)(2) Tie-In Guides > 1910.66(e)(2)(iii) > 1910.66(e)(2)(iii)(C) System Utilizing Angulated Roping and Building Face Rollers
JUMP TO FULL CODE CHAPTER
The system shall keep the equipment in continuous contact with the building facade, and shall prevent sudden horizontal movement of the platform. This system is acceptable only where the suspended portion of the equipment in use does not exceed 130 feet (39.6 m) above a safe surface or ground level, and where the platform maintains no less than 10 pounds (44.4 n) angulation force on the building facade.

Related Code Sections


1910.66(e)(2)(iii)(C) Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms, System Utilizing Angulated Roping and Building Face Rollers
The system shall keep the equipment in continuous contact with the building facade, and shall prevent sudden horizontal movement of the platform ...
OSHA 1910 General Industry > F Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms > 1910.66 Powered Platforms for Building Maintenance > 1910.66(e) Powered Platform Installations-Affected Parts of Buildings > 1910.66(e)(2) Tie-In Guides > 1910.66(e)(2)(iii) > 1910.66(e)(2)(iii)(C) System Utilizing Angulated Roping and Building Face Rollers
Appendix A Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms, Guidelines (Advisory)
guides are acceptable as tie-in guides in a building face for a continuous stabilization system. Internal guides are embedded in other building members ...
OSHA 1910 General Industry > F Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms > 1910.66 Powered Platforms for Building Maintenance > A Guidelines (Advisory)
1910.66(e)(2)(iii)(A) Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms,
of the stabilizer ties will not cause the platform suspension ropes to angulate the platform horizontally across the face of the building. The anchors shall ...
OSHA 1910 General Industry > F Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms > 1910.66 Powered Platforms for Building Maintenance > 1910.66(e) Powered Platform Installations-Affected Parts of Buildings > 1910.66(e)(2) Tie-In Guides > 1910.66(e)(2)(iii) > 1910.66(e)(2)(iii)(A)
1910.66(e)(2)(iii) Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms,
of the stabilizer ties will not cause the platform suspension ropes to angulate the platform horizontally across the face of the building. The anchors ...
OSHA 1910 General Industry > F Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms > 1910.66 Powered Platforms for Building Maintenance > 1910.66(e) Powered Platform Installations-Affected Parts of Buildings > 1910.66(e)(2) Tie-In Guides > 1910.66(e)(2)(iii)
1910.66(e)(2)(ii) Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms,
If angulated roping is employed, tie-in guides required in paragraph (e)(2)(i) of this section may be eliminated for not more than 75 feet (22.9 m ...
OSHA 1910 General Industry > F Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms > 1910.66 Powered Platforms for Building Maintenance > 1910.66(e) Powered Platform Installations-Affected Parts of Buildings > 1910.66(e)(2) Tie-In Guides > 1910.66(e)(2)(ii)
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING