406.7.2 System Location
JUMP TO FULL CODE CHAPTER
A soil absorption system shall be installed in the cut area of an altered site. A soil absorption system shall not be installed in the fill area of an altered site. The area of fill on an altered site is permitted to be used as a portion of the required 20-foot (6096 mm) separating distance from the crown of a critical slope. There shall be not less than 6 feet (1829 mm) of natural soil between the edge of a system area and the downslope side of the altered area.
Related Code Sections
406.7.2 Site Evaluation and Requirements, System Location
A soil absorption system shall be installed in the cut area of an altered site. A soil absorption system shall not be installed in the fill area ...
Private Sewage Disposal Code 2018 of South Holland > 4 Site Evaluation and Requirements > 406 Site Requirements > 406.7 Altering Slopes > 406.7.2 System Location
406.7.2 Site Evaluation and Requirements, System Location
A soil absorption system shall be installed in the cut area of an altered site. A soil absorption system shall not be installed in the fill area ...
Private Sewage Disposal Code 2012 of South Holland > 4 Site Evaluation and Requirements > 406 Site Requirements > 406.7 Altering Slopes > 406.7.2 System Location
(2) Special Equipment, Circulation and Sanitation System, Location
Receptacles that provide power for water-pump motors or for other loads directly related to the circulation and sanitation system shall be located ...
National Electrical Code 2014 of South Holland > 6 Special Equipment > 680 Swimming Pools, Fountains, and Similar Installations > 680.22 Lighting, Receptacles, and Equipment > (A) Receptacles > (2) Circulation and Sanitation System, Location
401.1.1 Gas Piping Installations, Utility Piping Systems Located Within Buildings
Utility service piping located within buildings shall be installed in accordance with the structural safety and fire protection provisions ...
Fuel Gas Code 2012 of South Holland > 4 Gas Piping Installations > 401 (IFGC) General > 401.1 Scope > 401.1.1 Utility Piping Systems Located Within Buildings
401.1.1 Gas Piping Installations, Utility Piping Systems Located Within Buildings
Utility service piping located within buildings shall be installed in accordance with the structural safety and fire protection provisions ...
Fuel Gas Code 2018 of South Holland > 4 Gas Piping Installations > 401 (IFGC) General > 401.1 Scope > 401.1.1 Utility Piping Systems Located Within Buildings