The maximum angular exposure of the grinding wheel periphery and sides for safety guards used on machines known as swing frame grinding machines shall not exceed 180 deg., and the top half of the wheel shall be enclosed at all times. (See Figures O-14 and O-15.)

Figure No. O-14                                              Figure No. O-15