5.3.1.7.2 Suspension or Support Means Having an Opening Facing Away From the Stair
Safety Code for Elevators and Escalators 2019 of Illinois > 5 Special Application Elevators > 5.3 Private Residence Elevators > 5.3.1 Private Residence Electric Elevators > 5.3.1.7 Guarding of Suspension Means and Other Equipment > 5.3.1.7.2 Suspension or Support Means Having an Opening Facing Away From the Stair
Go To Full Code Chapter
Suspension or support means that operate within a guide or track whose segments total a minimum of 270 deg shall be considered suitably guarded, provided that the centerline of the opening in the guide or track is 180 deg from the closest point of the stair. See Nonmandatory Appendix H, Figure H-l.
Related Code Sections
5.3.1.7.2 Special Application Elevators, Suspension or Support Means Having an Opening Facing Away From the Stair
Suspension or support means that operate within a guide or track whose segments total a minimum of 270 deg shall be considered suitably guarded ...
Safety Code for Elevators and Escalators 2019 of Illinois > 5 Special Application Elevators > 5.3 Private Residence Elevators > 5.3.1 Private Residence Electric Elevators > 5.3.1.7 Guarding of Suspension Means and Other Equipment > 5.3.1.7.2 Suspension or Support Means Having an Opening Facing Away From the Stair
620.41 Special Equipment, Suspension of Traveling Cables
looping the cables around supports for unsupported lengths less than 30 m (100 ft) By suspending from the supports by a means that automatically ...
620.41 Special Equipment, Suspension of Traveling Cables
for the hoistway suspension means shall be that length of cable measured from the point of suspension in the hoistway to the bottom of the loop ...
5.2.1.20.1 Special Application Elevators, Suspension Means
Cars shall be suspended by ropes attached to the car frame or passing around sheaves attached to the car frame specified in 2.15.1. Ropes that have ...
5.4.8 Special Application Elevators, Suspension Means
Where the chassis is suspended from the driving machine by a wire rope or roller chain, a single suspension means shall ...