• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1805.2.2.1 Surface Preparation of Walls

Building Code 2018 of Illinois > 18 Soils and Foundations > 1805 Dampproofing and Waterproofing > 1805.2 Dampproofing > 1805.2.2 Walls > 1805.2.2.1 Surface Preparation of Walls
JUMP TO FULL CODE CHAPTER
Prior to application of dampproofing materials on concrete walls, holes and recesses resulting from the removal of form ties shall be sealed with a bituminous material or other approved methods or materials. Unit masonry walls shall be parged on the exterior surface below ground level with not less than 3/8 inch (9.5 mm) of Portland cement mortar. The parging shall be coved at the footing.
Exception: Parging of unit masonry walls is not required where a material is approved for direct application to the masonry.

Related Code Sections


1805.2.2.1 Soils and Foundations, Surface Preparation of Walls
with a bituminous material or other approved methods or materials. Unit masonry walls shall be parged on the exterior surface below ground level ...
Building Code 2021 of Illinois > 18 Soils and Foundations > 1805 Dampproofing and Waterproofing > 1805.2 Dampproofing > 1805.2.2 Walls > 1805.2.2.1 Surface Preparation of Walls
1805.2.2.1 Soils and Foundations, Surface Preparation of Walls
with a bituminous material or other approved methods or materials. Unit masonry walls shall be parged on the exterior surface below ground level ...
Building Code 2018 of Illinois > 18 Soils and Foundations > 1805 Dampproofing and Waterproofing > 1805.2 Dampproofing > 1805.2.2 Walls > 1805.2.2.1 Surface Preparation of Walls
2510.7 Gypsum Board, Gypsum Panel Products and Plaster, Preparation of Masonry and Concrete
Surfaces shall be clean, free from efflorescence, sufficiently damp and rough for proper bond. If the surface is insufficiently rough, approved ...
Building Code 2021 of Illinois > 25 Gypsum Board, Gypsum Panel Products and Plaster > 2510 Lathing and Furring for Cement Plaster (Stucco) > 2510.7 Preparation of Masonry and Concrete
2510.7 Gypsum Board, Gypsum Panel Products and Plaster, Preparation of Masonry and Concrete
Surfaces shall be clean, free from efflorescence, sufficiently damp and rough for proper bond. If the surface is insufficiently rough, approved ...
Building Code 2018 of Illinois > 25 Gypsum Board, Gypsum Panel Products and Plaster > 2510 Lathing and Furring for Cement Plaster (Stucco) > 2510.7 Preparation of Masonry and Concrete
2513.6 Gypsum Board, Gypsum Panel Products and Plaster, Preparation of Masonry and Concrete
Masonry and concrete surfaces shall be prepared in accordance with the provisions of Section 2510.7 ...
Building Code 2021 of Illinois > 25 Gypsum Board, Gypsum Panel Products and Plaster > 2513 Exposed Aggregate Plaster > 2513.6 Preparation of Masonry and Concrete
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING