3304.4.1 Support of Excavation

NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3304 Soil and Foundation Work > 3304.4 Protection of Sides of Excavations > 3304.4.1 Support of Excavation
JUMP TO FULL CODE CHAPTER
The sides of all excavations, including related or resulting embankments, that are 5 feet (1524 mm) or greater in depth or height shall be supported in accordance with one or more of the following means. Where required by Section 3304.2, such means shall be indicated on drawings:

1. Sheeting, shoring, bracing, or by other retaining structures as may be necessary to prevent the sides of the excavation from caving in before permanent supports are provided. Such methods of protection shall be subject to special inspection in accordance with the provisions of Chapter 17; or

2. Excavation sides sloped not steeper than 45 degrees (0.79 rad) or stepped so that the average slope is not steeper than 45 degrees (0.79 rad) with no step more than 5 feet (1524 mm) high, provided such slope or step does not endanger any structure or temporary construction, including subsurface structures. Slopes or steps steeper than 45 degrees (0.79 rad), or steps more than 5 feet (1524 mm) high shall be permitted only where the registered design professional preparing the drawings required by Section 3304.2 determines, based upon the completion of a geotechnical investigation report acceptable to the commissioner, that the slopes or steps will be stable.

Exception: For a rock cut excavation, no protection is required, provided a registered design professional determines the rock cut will not be subject to shearing and will not otherwise be unstable before permanent supports are provided. Otherwise, the rock cut shall be stabilized in accordance with drawings prepared by the registered design professional.
Share URL

Copy and paste the link below into emails, chats or browsers.

Copy

You can also copy or bookmark the link from your browser's address bar.

Related Code Sections


1114.5.1 Storm Drainage, Support of Excavation
When an onsite stormwater disposal system installation requires an excavation deeper than 5 feet (1524 mm), the sides of the excavation shall ...
NYC Plumbing Code 2014 > 11 Storm Drainage > 1114 Private On-Site Stormwater Disposal Systems > 1114.5 On-Site Stormwater Disposal System Installation > 1114.5.1 Support of Excavation
3304.4.1 Safeguards During Construction or Demolition, Support of Excavation
The sides of all excavations, including related or resulting embankments, that are 5 feet (1524 mm) or greater in depth or height shall be supported ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3304 Soil and Foundation Work > 3304.4 Protection of Sides of Excavations > 3304.4.1 Support of Excavation
§28-105.2.1 Administration, Submittal Documents Required for Foundations and Earthwork
Prior to the issuance of any permit for work that includes foundations and/or earthwork, submittal documents clearly illustrating support ...
NYC General Admin. Provisions 2014 > 1 Administration > 105 Permits > §28-105.2 Classification of Work Permits > §28-105.2.1 Submittal Documents Required for Foundations and Earthwork
Section 3304 Safeguards During Construction or Demolition, Soil and Foundation Work
the earth, adjacent structures, and adjacent equipment. The use of slurry to support excavations shall be subject to special inspection in accordance ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3304 Soil and Foundation Work
3304.4.4 Safeguards During Construction or Demolition, Guardrail System
the sheeting, shoring, bracing, or any other support of excavation extends at least 5 1 / 2 inches (140 mm) above the top of the excavation. 3. A guardrail ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3304 Soil and Foundation Work > 3304.4 Protection of Sides of Excavations > 3304.4.4 Guardrail System
About UpCodes

UpCodes provides an intuitive resource to navigate building regulations.

Codes are organized by jurisdiction to help you understand which regulations apply to your project.


Find Your Codes
COMPANY INFO About Contact Careers Terms Privacy
CATEGORY General New York City New York State California Codes Building Codes Online
PREMIUM Features Pricing Sign Up Log In
CODES IBC 2015 IRC 2015 IPC 2015 California Building Code 2016 Popular Sections

FOLLOW US