// CODE SNIPPET
42-40 Supplementary Use Regulations and Special Provisions Applying Along District Boundaries
Go To Full Code ChapterSee More
42-41 Enclosure of Commercial or Manufacturing Activities
M1 M2 M3
In all districts, as indicated, all commercial or manufacturing activities established by development, enlargement, extension or change of use, except storage of materials or products, shall be subject to the provisions of this Section with respect to enclosure, except as otherwise specifically provided in the Use Groups permitted in the district, and in Sections 44-11 (General Provisions) and 44-51 (Permitted Accessory Off-street Loading Berths). With respect to the enlargement or extension of an existing use, such provisions shall apply to the enlarged or extended portion of such use.
42-411 In M1 Districts
M1
In the district indicated, all such activities shall be located within completely enclosed buildings, provided, however, that commercial uses may be located within buildings which are completely enclosed except for store fronts or store windows which may be opened to serve customers outside the building.
42-412 In M2 or M3 Districts
M2 M3
In the districts indicated, all such activities within 300 feet of a Residence District boundary shall be located within completely enclosed buildings, provided, however, that commercial uses may be located within buildings which are completely enclosed except for store fronts or store windows which may be opened to serve customers outside the building.
42-42 Enclosure or Screening of Storage
M1 M2 M3
In all districts, as indicated, all storage of materials or products established by development, enlargement, extension, change of use, or any new open storage or any increase in the portion of a zoning lot used for open storage, shall conform to the provisions of this Section. In addition, new accessory open storage or any increase in the portion of a zoning lot used for accessory open storage shall conform to the provisions of this Section.
With respect to the enlargement or extension of existing storage of materials or products, such provisions shall apply to the enlarged or extended portion of such storage.
42-421 In M1 Districts
M1
In the district indicated, storage of materials or products within 200 feet of a Residence District boundary shall be located within completely enclosed buildings.
42-422 In M2 or M3 Districts
M2 M3
In the districts indicated, and within 200 feet of a Residence District boundary, open storage of materials or products shall be permitted only if effectively screened by a solid wall or fence (including solid entrance and exit gates) at least eight feet in height.
42-44 Limitations on Business Entrances, Show Windows or Signs
M1 M2 M3
In all districts, as indicated, the location of primary business entrances, show windows, or signs shall be subject to the provisions of this Section. For the purposes of this Section, a lot of record or a group of contiguous lots of record held in single ownership or control at December 15, 1961, or any applicable amendment thereto, shall be considered a single zoning lot, regardless of any subsequent subdivision.
For the purposes of this Section, a corner lot shall include the entire zoning lot, notwithstanding the 100 foot limitation in the definition of corner lots in Section 12-10 (DEFINITIONS). All other zoning lots shall be considered zoning lots with single frontage.
The provisions of this Section shall not apply to:
- vehicular entrances or exits for permitted drive-in uses or automotive service establishments or for permitted or required accessory off-street parking spaces or loading berths;
- service entrances, or other entrances less than 3 feet, 6 inches in width;
- windows other than show windows; or
- ventilators, fire escapes or other appurtenances required by law.
42-441 For Zoning Lots With Single Frontage
M1 M2 M3
In all districts, as indicated, for zoning lots with single frontage, no primary business entrance, show window or sign shall be located on that portion of the street frontage within 20 feet of frontage on the same side of the street in a Residence District.
However, where the street frontage of such zoning lot or portion thereof located within the Manufacturing District is less than 30 feet in length, such minimum distance shall be reduced to 10 feet.
For zoning lots with a frontage of more than 30 feet, an application may be made to the Board of Standards and Appeals to reduce such minimum distance to 10 feet, as provided in Section 73-50 (SPECIAL PROVISIONS APPLYING ALONG DISTRICT BOUNDARIES).
42-442 For Corner Lots
M1 M2 M3
In all districts, as indicated, no primary business entrance, show window or sign shall be located on that portion of the street frontage of a corner lot within 75 feet of frontage on the same side of the street in a Residence District.
However, primary business entrances, show windows, or signs may be located on frontage less than 75 feet, but not less than 20 feet, from a Residence District boundary:
- if the total length of the block face containing such frontage is less than 220 feet; or
- if such frontage adjoins frontage on a corner lot in a Residence District; or
- if such frontage is separated from frontage in the Residence District by one or more zoning lots with single frontage.
42-45 Exceptions for Integrated Developments Divided by District Boundaries
M1 M2 M3
In all districts, as indicated, primary business entrances, show windows or signs may be located on any frontage within a Manufacturing District, if the Commissioner of Buildings finds that the zoning lot on which the business entrance, show window or sign is to be located:
- is divided by a boundary between the Manufacturing District and a Residence District; or
- is presently in the same ownership as adjoining property located in a Residence District, and no building in the Residence District exists, or will in the future be erected, within a distance of 75 feet from the Manufacturing District, as evidenced by deed restrictions filed in an office of record binding the owner and his heirs and assigns.
42-46 Air Space Over a Railroad or Transit Right-of-Way or Yard
42-461 Definitions
Words in italics are defined in Section 12-10 or, if applicable exclusively to this Chapter, in this Section.
42-462 Use of Railroad or Transit Air Space
M1 M2 M3
- In all districts, as indicated, railroad or transit air space may be developed or used only for a permitted use accessory to the railroad or transit right-of-way or yard, a use permitted by the City Planning Commission as set forth in Section 74-681 (Development within or over a railroad or transit right-of-way or yard), a railroad passenger station permitted by the City Planning Commission as set forth in Section 74-62 (Railroad Passenger Stations) or an open vehicle storage establishment authorized pursuant to this Section unless the right-of-way or yard or portion thereof is no longer required for railroad or transit use as set forth in paragraph (b) of this Section.
If any building or other structure constructed in such railroad or transit air space in accordance with the provisions of Section 74-681 is enlarged or replaced by a new building or other structure, the provisions of this Section shall apply to such enlargement or replacement.
However, any use legally established in such railroad or transit air space in accordance with the provisions of Section 74-681 may be changed to another use listed in a permitted Use Group, and no special permit from the Commission shall be required for such change of use.
Any building or other structure within or over a railroad or transit right-of-way or yard, which building or other structure was completed prior to September 27, 1962, or constructed in accordance with the applicable provisions of Sections 11-31 to 11-34, inclusive, prior to December 5, 1991, may be enlarged or replaced in accordance with the applicable district regulations without any requirement for a special permit from the Commission. Ownership of rights permitting the enlargement or replacement of such a building or other structure shall be deemed to be equivalent to ownership of a zoning lot or portion thereof, provided that such enlargement or replacement will be on one block and the rights are in single ownership and recorded prior to February 22, 1990. Such ownership of rights shall be deemed to include alternative ownership arrangements specified in the zoning lot definition of Section 12-10 (DEFINITIONS).
Enlargement or replacement utilizing these ownership rights shall be deemed to be constructed upon the equivalent of a zoning lot. - When the use of a railroad or transit right-of-way or yard, or portion thereof, has been permanently discontinued or terminated and a large-scale development requiring one or more special permits is proposed, no use or development of the property shall be allowed until the Commission has authorized the size and configuration of all zoning lots created on such property. As a condition for such authorization, the Commission shall find that:
- the proposed zoning lots, indicated by a map describing the boundaries of, and the total area of, each lot, are not excessively large, elongated or irregular in shape and that no development on any zoning lot would result in the potential for an excessive concentration of bulk that would be incompatible with allowable developments on adjoining property; and
- each resulting zoning lot has direct access to one or more streets.No subsequent alteration in size or configuration of any zoning lot approved by the Commission shall be permitted unless authorized by the Commission. The Commission may prescribe appropriate conditions and safeguards to minimize adverse effects of such zoning lot designation on the character of the surrounding area. Such conditions shall be set forth in a written Declaration of Restrictions covering all tracts of land or in separate written Declarations of Restrictions covering parts of such tracts of land and which in the aggregate cover the entire tract of land comprising the zoning lot and which is executed and recorded as specified in the definition of zoning lot in Section 12-10.Prior to granting any zoning lot authorization relating to such right-of-way or yard, the Commission shall request the Metropolitan Transportation Authority and the Departments of Transportation of the State of New York and the City of New York to indicate within 30 days whether said agencies have any plan to use such property or portion thereof for a railroad or transit use.
- In an M1-1 District, on the block bounded by Vanderbilt Avenue, Atlantic Avenue, Carlton Avenue and Pacific Street in the Borough of Brooklyn, the Commission may authorize the use of railroad or transit air space for an open vehicle storage establishment provided the Commission makes the following findings:
- that adequate access to one or more streets is provided;
- that access to such use is located on a street not less than 60 feet in width;
- that the proposed open vehicle storage establishment will result in reducing the number of vehicles standing on nearby streets; and
- that such establishment is located not less than 20 feet below curb level except for access ramps to the street or streets.For the purpose of this authorization a secondary access ramp may be permitted provided that the intersection of such ramp and the street shall be no more than two blocks from the intersection of the primary access ramp and a street.The Commission may prescribe appropriate conditions and safeguards to minimize any adverse effects on the character of the surrounding area, including requirements for the shielding of flood lights, screening, and surfacing of all access ramps or driveways.
- Notwithstanding the above, the High Line, as defined in Section 98-01, shall be governed by the provisions of Section 98-16 (Air Space Over a Railroad or Transit Right-of-way or Yard).
Upcodes Diagrams
Related Code Sections
3.3.286 Definitions, Supplementary
As used in this Code, supplementary refers to equipment or operations not required by this Code and designated as such by the authority having ...
Section E104 Supplementary Accessibility Requirements, Special Occupancies
shall be positioned for parallel approach to the side of the bed. Exception: This requirement shall not apply where a single clear floor space ...
Section E104 Supplementary Accessibility Requirements, Special Occupancies
Where dwelling units and sleeping
units are altered or added, the requirements of Section E104.2 shall apply only ...
Section E104 Supplementary Accessibility Requirements, Special Occupancies
space shall be positioned for parallel approach to the side of the bed.
Exception: This requirement shall not apply where a single clear floor ...
§27-295 Building Limitations, Mixed Districts
Any building located on the boundary line of a fire district, so that it is both inside and outside the district, shall be of a type of construction ...