// CODE SNIPPET
3314.4.2.2 Supervision of Supported Scaffold Use
JUMP TO FULL CODE CHAPTER
The use of a supported scaffold shall be supervised by a competent person designated by the scaffold controlling entity.
Related Code Sections
3314.4.2.2 Safeguards During Construction or Demolition, Supervision of Supported Scaffold Use
The use of a supported scaffold shall be supervised by a competent person designated by the scaffold controlling entity ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3314 Scaffolds > 3314.4 Installation, Inspection, Repair, Maintenance, Adjustment, Use, and Removal of Scaffolds > 3314.4.2 Use of Scaffolds > 3314.4.2.2 Supervision of Supported Scaffold Use
3314.4.2.2 Safeguards During Construction or Demolition, Supervision of Supported Scaffold Use
The use of a supported scaffold shall be supervised by a competent person designated by the scaffold controlling entity ...
NYC Building Code 2022 > 33 Safeguards During Construction or Demolition > 3314 Scaffolds > 3314.4 Installation, Inspection, Repair, Maintenance, Adjustment, Use, and Removal of Scaffolds > 3314.4.2 Use of Scaffolds > 3314.4.2.2 Supervision of Supported Scaffold Use
3314.4.2.5 Safeguards During Construction or Demolition, Training
All individuals using a supported scaffold or an adjustable suspended scaffold, including the person supervising such use, shall have been trained ...
NYC Building Code 2022 > 33 Safeguards During Construction or Demolition > 3314 Scaffolds > 3314.4 Installation, Inspection, Repair, Maintenance, Adjustment, Use, and Removal of Scaffolds > 3314.4.2 Use of Scaffolds > 3314.4.2.5 Training
3314.4.3.5 Safeguards During Construction or Demolition, Pre-Shift Inspection for a Supported Scaffold
by the competent person supervising the use of the scaffold in accordance with
Section 3314.4.2.2 to verify the scaffold, all components of and attachments ...
NYC Building Code 2022 > 33 Safeguards During Construction or Demolition > 3314 Scaffolds > 3314.4 Installation, Inspection, Repair, Maintenance, Adjustment, Use, and Removal of Scaffolds > 3314.4.3 Inspections > 3314.4.3.5 Pre-Shift Inspection for a Supported Scaffold
3314.4.3.5 Safeguards During Construction or Demolition, Pre-Shift Inspection for a Supported Scaffold
Prior to each shift the supported scaffold shall be inspected by the competent person supervising the use of the scaffold in accordance with Section ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3314 Scaffolds > 3314.4 Installation, Inspection, Repair, Maintenance, Adjustment, Use, and Removal of Scaffolds > 3314.4.3 Inspections > 3314.4.3.5 Pre-Shift Inspection for a Supported Scaffold