8104.1 Classification of Supervised Living Facilities
Supervised living facilities are classified in accordance with Chapter 2 and must meet the fire safety requirements for the designated occupancy classification.
8104.1.1 Class A-1 Supervised Living Facilities
Class A-1 supervised living facilities must meet Group R-3 occupancy requirements.
8104.1.2 Class A-2 Supervised Living Facilities
Class A-2 supervised living facilities housing not more than 16 persons, excluding staff, must meet Group R-4 occupancy requirements. Class A-2 supervised living facilities housing more than 16 persons, excluding staff, must meet Group I-1 occupancy requirements.
8104.1.3 Class B-1 Supervised Living Facilities
Class B-1 supervised living facilities meeting the fire-protection provisions of Chapter 32 of the National Fire Protection Association Standard No. 101 (Quincy, Massachusetts, 2000) for impractical evacuation capabilities shall be classified as Group R-3 occupancies. For the purposes of Sections 8104.1.3 and 8104.1.4, Standard No. 101 (2000) Chapter 32 is incorporated by reference, is not subject to frequent change and is available at the State Law Library, 25 Rev. Dr. Martin Luther King Jr. Blvd., Saint Paul, Minnesota 55155.
8104.1.4 Class B-2 Supervised Living Facilities
Class B-2 supervised living facilities meeting the fire-protection provisions of Chapter 32 of the National Fire Protection Association Standard No. 101 (Quincy, Massachusetts, 2000) for impractical evacuation capabilities shall be classified as Group R-4 occupancies.
8104.1.5 Class B-3 Supervised Living Facilities
Class B-3 supervised living facilities must meet Group I-2 occupancy requirements.