Sunrooms shall be categorized in one of the following categories by the permit applicant, design professional, or the property owner where the sunroom is being constructed:
  • A roof or a covering of an outdoor space. The openings shall be permitted to be enclosed with insect screening or 0.5 mm (20 mil) maximum thickness plastic film. The space is defined as nonhabitable and unconditioned.
  • A roof or a covering of an outdoor space with enclosed walls. The openings are permitted to be enclosed with translucent or transparent plastic or glass. The space is defined as nonhabitable and unconditioned.
  • A roof or a covering of an outdoor space with enclosed walls. The openings are permitted to be enclosed with translucent or transparent plastic or glass. The sunroom complies with additional requirements for forced entry resistance, air leakage resistance and water penetration resistance. The space is defined as nonhabitable and unconditioned.
  • A roof or a covering of an outdoor space with enclosed walls. The sunroom is designed to be heated and/or cooled by a separate temperature control or system and is thermally isolated from the primary structure. The sunroom complies with additional requirements for forced entry resistance, water penetration resistance, air leakage resistance, and thermal performance. The space is defined as habitable and conditioned.
  • A roof or a covering of an outdoor space with enclosed walls. The sunroom is designed to be heated and/or cooled and is open to the main structure. The sunroom complies with additional requirements for forced entry resistance, water penetration resistance, air leakage resistance, and thermal performance. The space is defined as habitable and conditioned.

Related Code Sections

2003.9.2 Aluminum, Sunroom Categories
Sunrooms shall be categorized in one of the following categories by the permit applicant, design professional, or the property owner where ...
2003.9.2 Aluminum, Sunroom Categories
Sunrooms shall be categorized in one of the following categories by the permit applicant, design professional, or the property owner where ...
2003.9.2 Aluminum, Sunroom Categories
Sunrooms shall be categorized in one of the following categories by the permit applicant, design professional, or the property owner where ...
2002.6 Aluminum, Sunroom Design
For the purpose of applying the criteria of the AAMA/NPEA/NSA 2100, sunrooms shall be categorized in one of the following categories by the permit ...