• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

Section P3303 Sumps and Pumping Systems

Residential Code 2018 of Kansas > 33 Storm Drainage > P3303 Sumps and Pumping Systems
JUMP TO FULL CODE CHAPTER

P3303.1 Pumping System

The sump pump, sump and discharge piping shall conform to Sections P3303.1.1 through P3303.1.4.

P3303.1.1 Pump Capacity and Head

The sump pump shall be of a capacity and head appropriate to anticipated use requirements.

P3303.1.2 Sump Pit

The sump shall be not less than 18 inches (457 mm) in diameter and 24 inches (610 mm) deep, unless otherwise approved. The sump shall be accessible and located so that all drainage flows into the sump by gravity. The sump shall be constructed of tile, steel, plastic, cast iron, concrete or other approved material, with a removable cover adequate to support anticipated loads in the area of use. The sump floor shall be solid and provide permanent support for the pump.

P3303.1.3 Electrical

Electrical outlets shall meet the requirements of Chapters 34 through 43.

P3303.1.4 Piping

Discharge piping shall meet the requirements of Sections P3002.1, P3002.2, P3002.3 and P3003. Discharge piping shall include an accessible full flow check valve. Pipe and fittings shall be the same size as, or larger than, the pump discharge tapping.

Related Code Sections


Section 1113 Storm Drainage, Sumps and Pumping Systems
The sump pump, pit and discharge piping shall conform to Sections 1113.1.1 through 1113.1.4 ...
Plumbing Code 2018 of Kansas > 11 Storm Drainage > 1113 Sumps and Pumping Systems
Section P3303 Storm Drainage, Sumps and Pumping Systems
The sump pump, sump and discharge piping shall conform to Sections P3303.1.1 through P3303.1.4 ...
Residential Code 2018 of Kansas > 33 Storm Drainage > P3303 Sumps and Pumping Systems
P3303.1.1 Storm Drainage, Pump Capacity and Head
The sump pump shall be of a capacity and head appropriate to anticipated use requirements ...
Residential Code 2018 of Kansas > 33 Storm Drainage > P3303 Sumps and Pumping Systems > P3303.1 Pumping System > P3303.1.1 Pump Capacity and Head
1113.1.3 Storm Drainage, Electrical
Electrical service outlets, where required, shall meet the requirements of NFPA 70 ...
Plumbing Code 2018 of Kansas > 11 Storm Drainage > 1113 Sumps and Pumping Systems > 1113.1 Pumping System > 1113.1.3 Electrical
1113.1.4 Storm Drainage, Piping
and fittings shall be the same size as, or larger than, the pump discharge tapping. Exception: In one- and two-family dwellings, only a check valve ...
Plumbing Code 2018 of Kansas > 11 Storm Drainage > 1113 Sumps and Pumping Systems > 1113.1 Pumping System > 1113.1.4 Piping
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE