• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1134A.4 Sufficient Maneuvering Space

Los Angeles Building Code > 11A Housing Accessibility > 1134A Bathing and Toilet Facilities > 1134A.4 Sufficient Maneuvering Space
JUMP TO FULL CODE CHAPTER

Bathing and toilet facilities required to be adaptable shall provide sufficient maneuvering space for a person using a wheelchair or other mobility aid to enter and close the door, use the fixtures, reopen the door and exit.

Where the door swings into the bathroom or powder room, there shall be a clear maneuvering space outside the swing of the door of at least 30 inches by 48 inches (762 mm by 1219 mm) within the room. The clear maneuvering space shall allow the user to position a wheelchair or other mobility aid clear of the path of the door as it is closed and to permit use of fixtures.

Doors may swing into the required clear space at any fixture when a clear maneuvering space is provided outside the swing arc of the door so it can be closed.

Maneuvering spaces may include any knee space or toe space available below bathroom fixtures.

Related Code Sections


1134A.4 Housing Accessibility, Sufficient Maneuvering Space
Bathing and toilet facilities required to be adaptable shall provide sufficient maneuvering space for a person using a wheelchair or other mobility ...
Los Angeles Building Code > 11A Housing Accessibility > 1134A Bathing and Toilet Facilities > 1134A.4 Sufficient Maneuvering Space
11B-1002.4.4.2 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Side Entry
Where wheelchair spaces are entered only from the side, amusement rides shall be designed to permit sufficient maneuvering clearance for individuals ...
Los Angeles Building Code > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-1002 Amusement Rides > 11B-1002.4 Wheelchair Spaces in Amusement Rides > 11B-1002.4.4 Clearances > 11B-1002.4.4.2 Side Entry
11B-305.7 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Maneuvering Clearance
Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance ...
Los Angeles Building Code > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-305 Clear Floor or Ground Space > 11B-305.7 Maneuvering Clearance
1126A.3 Housing Accessibility, Maneuvering Clearances
on the approach side of the door or gate. (See Figure 11A-8A(a).) Strike edge maneuvering space. The width of the level area on the side to which ...
Los Angeles Building Code > 11A Housing Accessibility > 1126A Doors, Gates and Windows > 1126A.3 Maneuvering Clearances
11B-404.2.4 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Maneuvering Clearances
Minimum maneuvering clearances at doors and gates shall comply with Section 11B -404.2.4. Maneuvering clearances shall extend the full width ...
Los Angeles Building Code > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-404 Doors, Doorways, and Gates > 11B-404.2 Manual Doors, Doorways, and Manual Gates > 11B-404.2.4 Maneuvering Clearances
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE