7.3.1.1.1
The total capacity of the means of egress for any story, balcony, tier, or other occupied space shall be sufficient for the occupant load thereof unless one of the following conditions exists:
  1. The authority having jurisdiction shall be permitted to establish the occupant load as the number of persons for which existing means of egress is adequate, provided that measures are established to prevent occupancy by a greater number of persons.
  2. The egress capacity shall have been previously approved as being adequate.
7.3.1.1.2
For other than existing means of egress, where more than one means of egress is required, the means of egress shall be of such width and capacity that the loss of any one means of egress leaves available not less than 50 percent of the required capacity.

Related Code Sections

7.3.1.1 Means of Egress, Sufficient Capacity
The total capacity of the means of egress for any story, balcony, tier, or other occupied space shall be sufficient for the occupant load thereof ...
3.24.2.1 Hydraulic Elevators, Capacity
Tanks shall be of sufficient capacity to provide for an adequate liquid reserve in order to prevent the entrance of air or other gas into the system ...
(1) Special Equipment, Capacity
The generator shall have sufficient capacity to allow normal starting and running of the motor(s) driving the fire pump(s) while supplying all other ...
3003.1.3 Elevators and Conveying Systems, Two or More Elevators
seconds after failure of normal power where the standby power source is of sufficient capacity to operate all elevators at the same time. Where the standby ...
606.2.3 Building Services and Systems, Two or More Elevators
seconds after failure of normal power where the standby power source is of sufficient capacity to operate all elevators at the same time. Where the standby ...