711.0 Suds Relief

California Plumbing Code 2016 > 7 Sanitary Drainage > 711.0 Suds Relief
JUMP TO FULL CODE CHAPTER

711.1 General

Drainage connections shall not be made into a drainage piping system within 8 feet (2438 mm) of a vertical to horizontal change of direction of a stack containing suds-producing fixtures. Bathtubs, laundries, washing machine standpipes, kitchen sinks, and dishwashers shall be considered suds-producing fixtures. Where parallel vent stacks are required, they shall connect to the drainage stack at a point 8 feet (2438 mm) above the lowest point of the drainage stack.

Exceptions:
  1. Single-family residences
  2. Stacks receiving the discharge from less than three stories of plumbing fixtures
Share URL

Copy and paste the link below into emails, chats or browsers.

Copy

You can also copy or bookmark the link from your browser's address bar.

Related Code Sections


711.0 Sanitary Drainage, Suds Relief
of a stack containing suds-producing fixtures. Bathtubs, laundries, washing machine standpipes, kitchen sinks, and dishwashers shall be considered suds ...
California Plumbing Code 2016 > 7 Sanitary Drainage > 711.0 Suds Relief
1009.4 Traps and Interceptors, Relief Vent
Interceptors (clarifiers) shall be so designed that they will not become air-bound where closed covers are used. Each interceptor (clarifier) shall ...
California Plumbing Code 2016 > 10 Traps and Interceptors > 1009.0 Interceptors (Clarifiers) and Separators > 1009.4 Relief Vent
1112.10.3 Refrigeration, Internal Relief
Pressure-relief valves designed to discharge from a higher-pressure vessel into a lower pressure vessel internal to the system shall comply ...
California Mechanical Code 2016 > 11 Refrigeration > 1112.0 Pressure-Relief Devices > 1112.10 Discharge from Pressure-Relief Devices > 1112.10.3 Internal Relief
5303.16.12 Compressed Gases, Relief vents
Vent pipes for equipment in the vault shall terminate not less than 12 feet (3658 mm) above ground level ...
California Fire Code 2016 > 53 Compressed Gases > 5303 General Requirements > 5303.16 Vaults > 5303.16.12 Relief vents
5706.5.3.1.2 Flammable and Combustible Liquids, Hydrostatic relief
Hydrostatic pressure-limiting or relief devices shall be provided where pressure buildup in trapped sections of the system could exceed the design ...
California Fire Code 2016 > 57 Flammable and Combustible Liquids > 5706 Special Operations > 5706.5 Bulk transfer and process transfer operations > 5706.5.3 Process transfer > 5706.5.3.1 Piping, valves, hoses and fittings > 5706.5.3.1.2 Hydrostatic relief
About UpCodes

UpCodes provides an intuitive resource to navigate building regulations.

Codes are organized by jurisdiction to help you understand which regulations apply to your project.


Find Your Codes
COMPANY INFO About Free Law Contact Careers Terms Privacy Press Kit
CATEGORY General New York City New York State California Codes Building Codes Online
PREMIUM Features Pricing Sign Up Log In
CODES IBC 2015 IRC 2015 IPC 2015 California Building Code 2016 Popular Sections

FOLLOW US