The surface grade of soil absorption systems shall be located at a point lower than the surface grade of any water well or reservoir on the same or adjoining lot. Where this is not possible, the site shall be located so surface water drainage from the site is not directed toward a well or reservoir. The soil absorption system shall be located with a minimum horizontal distance between various elements as indicated in Table P3009.9. Private sewage disposal systems in compacted areas, such as parking lots and driveways, are prohibited. Surface water shall be diverted away from any soil absorption site on the same or neighboring lots.
LOCATION OF SUBSURFACE IRRIGATION SYSTEM
ELEMENTMINIMUM HORIZONTAL DISTANCE
STORAGE TANK
(feet)
IRRIGATION
DISPOSAL
FIELD(feet)
Buildings52
Lot line adjoining private property55
Water wells50100
Streams and lakes5050
Seepage pits55
Septic tanks05
Water service55
Public water main1010
For SI: 1 foot = 304.8 mm.

Related Code Sections

P3009.9 Sanitary Drainage, Subsurface Landscape Irrigation Site Location
absorption site on the same or neighboring lots. TABLE P3009.9 LOCATION OF SUBSURFACE IRRIGATION SYSTEM ELEMENT MINIMUM HORIZONTAL DISTANCE ...
Section 1401 Subsurface Landscape Irrigation Systems, General
The provisions of this chapter shall govern the materials, design, construction and installation of subsurface landscape irrigation systems connected ...
Chapter 14 Subsurface Landscape Irrigation Systems
User note: About this chapter: Chapter 14 provides regulations for disposing of nonpotable water to underground landscape irrigation piping ...
Section 1403 Subsurface Landscape Irrigation Systems, Installation
Absorption systems shall be installed in accordance with Sections 1403.1.1 through 1403.1.5 to provide landscape irrigation without surfacing ...