• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

506.2.3 Substantial Structural Damage to Vertical Load-Carrying Components

2010 Existing Building Code of NY > 5 Repairs > 506 Structural > 506.2 Repairs to Damaged Buildings > 506.2.3 Substantial Structural Damage to Vertical Load-Carrying Components
JUMP TO FULL CODE CHAPTER
Vertical load-carrying components that have sustained substantial structural damage shall be rehabilitated to comply with the applicable provisions for dead and live loads in the Building Code of New York State . Undamaged vertical load-carrying components that receive dead or live loads from rehabilitated components shall also be rehabilitated to carry the design loads of the rehabilitation design. New structural members and connections required by this rehabilitation design shall comply with the detailing provisions of the Building Code of New York State for new buildings of similar structure, purpose and location.

506.2.3.1 Lateral-Force-Resisting Elements

Regardless of the level of damage to vertical elements of the lateral-force-resisting system, if substantial structural damage to vertical load-carrying components was caused primarily by wind or seismic effects, then the building shall be evaluated in accordance with Section 506.2.2.1 and, if noncompliant, rehabilitated in accordance with Section 506.2.2.3.

Related Code Sections


506.2.3 Repairs, Substantial Structural Damage to Vertical Load-Carrying Components
Vertical load-carrying components that have sustained substantial structural damage shall be rehabilitated to comply with the applicable provisions ...
2010 Existing Building Code of NY > 5 Repairs > 506 Structural > 506.2 Repairs to Damaged Buildings > 506.2.3 Substantial Structural Damage to Vertical Load-Carrying Components
405.2.4 Repairs, Substantial Structural Damage to Gravity Load-Carrying Components
Gravity load-carrying components that have sustained substantial structural damage shall be rehabilitated to comply with the applicable provisions ...
2020 Existing Building Code of NYS > 4 Repairs > 405 Structural > 405.2 Repairs to Damaged Buildings > 405.2.4 Substantial Structural Damage to Gravity Load-Carrying Components
404.3 Prescriptive Compliance Method, Substantial Structural Damage to Gravity Load-Carrying Components
Gravity load-carrying components that have sustained substantial structural damage shall be rehabilitated to comply with the applicable provisions ...
Existing Building Code 2015 of New York State > 4 Prescriptive Compliance Method > 404 Repairs > 404.3 Substantial Structural Damage to Gravity Load-Carrying Components
Section 405 Repairs, Structural
Regardless of the level of damage to vertical elements of the lateral force-resisting system, if substantial structural damage to gravity load-carrying ...
2020 Existing Building Code of NYS > 4 Repairs > 405 Structural
405.2 Repairs, Repairs to Damaged Buildings
to vertical elements of the lateral force-resisting system, if substantial structural damage to gravity load-carrying components was caused primarily ...
2020 Existing Building Code of NYS > 4 Repairs > 405 Structural > 405.2 Repairs to Damaged Buildings
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING