Where the work area exceeds 50 percent of the building area and where work involves a substantial structural alteration, the lateral load-resisting system of the altered building shall satisfy the requirements of Sections 1609 and 1613 of the International Building Code. Reduced seismic forces shall be permitted.
Exceptions:
  1. Buildings of Group R occupancy with not more than five dwelling or sleeping units used solely for residential purposes that are altered based on the conventional light-frame construction methods of the International Building Code or in compliance with the provisions of the International Residential Code.
  2. Where the intended alteration involves only the lowest story of a building, only the lateral load-resisting components in and below that story need comply with this section.

Related Code Sections

503.11 Prescriptive Compliance Method, Substantial Structural Alteration
Where the work area exceeds 50 percent of the building area and where work involves a substantial structural alteration, the lateral load-resisting ...
503.11 Prescriptive Compliance Method, Substantial Structural Alteration
Where the work area exceeds 50 percent of the building area and where work involves a substantial structural alteration, the lateral load-resisting ...
906.2 Alterations—Level 3, Existing Structural Elements Resisting Lateral Loads
Where work involves a substantial structural alteration, the lateral load-resisting system of the altered building shall be shown to satisfy ...
906.2 Alterations—Level 3, Existing Structural Elements Resisting Lateral Loads
Where work involves a substantial structural alteration, the lateral load-resisting system of the altered building shall be shown to satisfy ...
Section 503 Prescriptive Compliance Method, Alterations
, any alteration that constitutes substantial improvement of the existing structure shall comply with the flood design requirements for new ...