// CODE SNIPPET
503.2.10 Substandard Width Roads
JUMP TO FULL CODE CHAPTER
Buildings on fire apparatus access roads that have an unobstructed roadway width of less than 34 feet (10 363 mm) shall be protected throughout by a sprinkler system. Buildings served by a substandard width fire apparatus access road that is a lawfully existing condition pursuant to FC 102.3, 102.4 and 102.5 shall comply with this requirement when undergoing alteration or a change of occupancy in accordance with FC501.4.3. This requirement shall not apply to any detached, unheated, carport, garden shed, greenhouse, private parking garage for not more than three motor vehicles, tower or other accessory building, that is:
Related Code Sections
1010.5.1 Means of Egress, Width
The minimum width of a means of egress ramp shall not be less than that required for corridors by Section 1016.2. The clear width of a ramp ...
NYC Building Code 2008 > 10 Means of Egress > 1010 Ramps > 1010.5 Minimum Dimensions > 1010.5.1 Width
1010.5.1 Means of Egress, Width
The minimum width of a means of egress ramp shall not be less than that required for corridors by Section 1018.2. The clear width of a ramp between ...
NYC Building Code 2014 > 10 Means of Egress > 1010 Ramps > 1010.5 Minimum Dimensions > 1010.5.1 Width
1012.6.2 Means of Egress, Width
The landing width shall be not less than the width
of the widest ramp run adjoining the landing ...
1020.2 Means of Egress, Width
The width of exit passageways shall be determined as specified in Section 1005.1 but such width shall not be less than 44 inches (1118 mm), except ...
1023.2 Means of Egress, Width
The width of exit passageways shall be determined as specified in Section 1005.1 but such width shall not be less than 44 inches (1118 mm), except ...