• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1704.5 Submittals to the Building Official

Building Code 2018 of Illinois > 17 Special Inspections and Tests > 1704 Special Inspections and Tests, Contractor Responsibility and Structural Observation > 1704.5 Submittals to the Building Official
JUMP TO FULL CODE CHAPTER
In addition to the submittal of reports of special inspections and tests in accordance with Section 1704.2.4, reports and certificates shall be submitted by the owner or the owner's authorized agent to the building official for each of the following:
  1. Certificates of compliance for the fabrication of structural, load-bearing or lateral load-resisting members or assemblies on the premises of an approved fabricator in accordance with Section 1704.2.5.1.
  2. Certificates of compliance for the seismic qualification of nonstructural components, supports and attachments in accordance with Section 1705.13.2.
  3. Certificates of compliance for designated seismic systems in accordance with Section 1705.13.3.
  4. Reports of preconstruction tests for shotcrete in accordance with Section 1908.5.
  5. Certificates of compliance for open web steel joists and joist girders in accordance with Section 2207.5.
  6. Reports of material properties verifying compliance with the requirements of AWS D1.4 for weldability as specified in Section 26.6.4 of ACI 318 for reinforcing bars in concrete complying with a standard other than ASTM A706 that are to be welded.
  7. Reports of mill tests in accordance with Section 20.2.2.5 of ACI 318 for reinforcing bars complying with ASTM A615 and used to resist earthquake-induced flexural or axial forces in the special moment frames, special structural walls or coupling beams connecting special structural walls of seismic force-resisting systems in structures assigned to Seismic Design Category B, C, D, E or F.

Related Code Sections


1704.5 Special Inspections and Tests, Submittals to the Building Official
be submitted by the owner or the owner's authorized agent to the building official for each of the following: Certificates of compliance ...
Building Code 2021 of Illinois > 17 Special Inspections and Tests > 1704 Special Inspections and Tests, Contractor Responsibility and Structural Observation > 1704.5 Submittals to the Building Official
1704.5 Special Inspections and Tests, Submittals to the Building Official
be submitted by the owner or the owner's authorized agent to the building official for each of the following: Certificates of compliance ...
Building Code 2018 of Illinois > 17 Special Inspections and Tests > 1704 Special Inspections and Tests, Contractor Responsibility and Structural Observation > 1704.5 Submittals to the Building Official
107.3.4.1 Scope and Administration, Deferred Submittals
Deferral of any submittal items shall have the prior approval of the building official . The registered design professional in responsible charge ...
Building Code 2021 of Illinois > 1 Scope and Administration > 107 Construction Documents > 107.3 Examination of Documents > 107.3.4 Design Professional in Responsible Charge > 107.3.4.1 Deferred Submittals
107.3.4.1 Scope and Administration, Deferred Submittals
Deferral of any submittal items shall have the prior approval of the building official . The registered design professional in responsible charge ...
Building Code 2018 of Illinois > 1 Scope and Administration > 107 Submittal Documents > 107.3 Examination of Documents > 107.3.4 Design Professional in Responsible Charge > 107.3.4.1 Deferred Submittals
2207.5 Steel, Certification
for submittal to the building official as specified in Section 1704.5 stating that work was performed in accordance with approved construction ...
Building Code 2021 of Illinois > 22 Steel > 2207 Steel Joists > 2207.5 Certification
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING