§27-723 Subgrade for Footings, Foundation Piers, and Foundation Walls

Jump To Full Code Chapter
The soil material directly underlying footings, foundation piers, and foundation walls shall be inspected by an architect or engineer after excavation and immediately prior to construction of the footings. If such inspection indicates that the soil conditions do not conform to those assumed for purposes of design and described on the plans, or are unsatisfactory due to disturbance, then additional excavation, reduction in allowable bearing pressure, or other remedial measures shall be adopted, as required. A copy of a report or reports on such inspection or inspections describing the conditions found and any necessary modification of the design, and bearing the signature of the architect or engineer making the inspections, shall be filed with the commissioner. In addition, notification shall be received by the department at least two working days prior to construction of the footing, pier, or foundation walls, that the subgrade is ready for inspection unless the requirements of section 27-209 of article twenty-one of subchapter one of this chapter have been met.

Related Code Sections

§27-723 Foundations, Subgrade for Footings, Foundation Piers, and Foundation Walls
The soil material directly underlying footings, foundation piers, and foundation walls shall be inspected by an architect or engineer after ...
§27-684 Foundations, Footings
Inspections of subgrade of footings, piers and walls shall comply with the requirements of section 27-723 of article thirteen of this subchapter ...
1805.5 Soils and Foundations, Foundation Walls
Concrete and masonry foundation walls shall be designed in accordance with Chapter 19 or 21, respectively ...
1805.5 Soils and Foundations, Shallow Foundations
The thickness of plain concrete footings supporting walls of other than light-frame construction shall not be less than 8 inches (203 ...
1809.5 Soils and Foundations, Shallow Foundations
The thickness of plain concrete footings supporting walls of other than light-frame construction shall not be less than 8 inches ...