Where elevator service is not provided in a structure, only the dwelling units and sleeping units that are located on stories indicated in Sections 1108.7.1.1 and 1108.7.1.2 are required to be Type A units and Type B units, respectively. The number of Type A units shall be determined in accordance with Section 1108.6.2.2.1.
1108.7.1.1 One Story With Type B Units Required
At least one story containing dwelling units or sleeping units intended to be occupied as a residence shall be provided with an accessible entrance from the exterior of the structure and all units intended to be occupied as a residence on that story shall be Type B units.
1108.7.1.2 Additional Stories With Type B Units
Where stories have entrances not included in determining compliance with Section 1108.7.1.1, and such entrances are proximate to arrival points intended to serve units on that story, as indicated in Items 1 and 2, all dwelling units and sleeping units intended to be occupied as a residence served by that entrance on that story shall be Type B units.
  1. Where the slopes of the undisturbed site measured between the planned entrance and all vehicular or pedestrian arrival points within 50 feet (15 240 mm) of the planned entrance are 10 percent or less.
  2. Where the slopes of the planned finished grade measured between the entrance and all vehicular or pedestrian arrival points within 50 feet (15 240 mm) of the planned entrance are 10 percent or less.
Where arrival points are not within 50 feet (15 240 mm) of the entrance, the closest arrival point shall be used to determine access unless that arrival point serves the story required by Section 1108.7.1.1.

Related Code Sections

1107.7.1 Accessibility, Structures Without Elevator Service
Where elevator service is not provided in a structure, only the dwelling units and sleeping units that are located on stories indicated in Sections ...
1108.7.1 Accessibility, Structures Without Elevator Service
Where elevator service is not provided in a structure, only the dwelling units and sleeping units that are located on stories indicated in Sections ...
(A) Special Equipment, Elevators
and are of a jacketed and flame-retardant type. (c) The following wiring methods shall be permitted in the hoistway in lengths not to exceed 1.8 m (6 ft ...
(A) Special Equipment, Elevators
and are of a jacketed and flame-retardant type. (c) The following wiring methods shall be permitted in the hoistway in lengths not to exceed 1.8 m (6 ft ...