Where a wall of a dwelling or structure serves as part of the barrier and where doors or windows provide direct access to the pool or spa through that wall, one of the following shall be required:
  1. Operable windows having a sill height of less than 48 inches (1219 mm) above the indoor finished floor and doors shall have an alarm that produces an audible warning when the window, door or their screens are opened. The alarm shall be listed and labeled as a water hazard entrance alarm in accordance with UL 2017. In dwellings or structures not required to be Accessible units, Type A units or Type B units, the operable parts of the alarm deactivation switches shall be located 54 inches (1372 mm) or more above the finished floor. In dwellings or structures required to be Accessible units, Type A units or Type B units, the operable parts of the alarm deactivation switches shall be located not greater than 54 inches (1372 mm) and not less than 48 inches (1219 mm) above the finished floor.
  2. A safety cover that is listed and labeled in accordance with ASTM F1346 is installed for the pools and spas.
  3. An approved means of protection, such as self-closing doors with self-latching devices, is provided. Such means of protection shall provide a degree of protection that is not less than the protection afforded by Item 1 or 2.

Related Code Sections

305.4 General Compliance, Structure Wall as a Barrier
Where a wall of a dwelling or structure serves as part of the barrier and where doors or windows provide direct access to the pool or spa through ...
7.2 Fire Barrier Walls, Continuity
The fire barrier wall shall be permitted to terminate at an individually protected structural member in the same ...
701.2 Fire and Smoke Protection Features, Fire-Resistance-Rated Construction
The fire-resistance rating of the following fire-resistance-rated construction shall be maintained: Structural members. Exterior walls. Fire ...
2110.1.1 Masonry, Limitations
Solid or hollow approved glass block shall not be used in fire walls, party walls, fire barriers, fire partitions or smoke barriers, or for load ...
2110.1.1 Masonry, Limitations
Solid or hollow approved glass block shall not be used in fire walls, party walls, fire barriers, fire partitions or smoke barriers, or for load ...