14-121 Structural Requirements for Enclosed Sidewalk Cafes
JUMP TO FULL CODE CHAPTER
The regulations of this Section governing certain structural and operational requirements shall apply to all enclosed sidewalk cafes.
- Ceiling
The ceiling of an enclosed sidewalk cafe shall be of incombustible materials, including colored or colorless safety glass or fabric which has been treated to be fire resistant as approved by the Department of Buildings.
At no point shall the height of the ceiling of an enclosed sidewalk cafe be lower than 7 feet, 0 inches above the floor of the sidewalk cafe. - Transparency — exterior walls
An enclosed sidewalk cafe may provide a base wall of opaque material up to a maximum height of 12 inches from the finished floor level. The base wall shall include any horizontal structural members that support transparent materials above.
All enclosing walls, doors and windows, except for the structural members, above finished floor level or base wall as provided in this Section, up to a height of 7 feet, 0 inches above finished floor level, must be of colorless, untinted, non-reflective, transparent material, as approved by the Department of Buildings. In order to maximize transparency, the horizontal as well as vertical structural members shall not be sized more than 10 inches wide.
At least 50 percent of the walls, up to a height of 7 feet, 0 inches above finished floor level, shall consist of operable transparent windows. - Elevation
The enclosed sidewalk cafe floor shall not be more than seven inches above the level of the adjoining sidewalk.
In the event of a major grade change, however, the City Planning Commission may, by certification, permit the floor level to be more than seven inches above the level of the adjoining sidewalk. - Designated boundaries
No portion of enclosed sidewalk cafes, such as doors, windows, walls or any objects placed within an enclosed sidewalk cafe, shall swing or project beyond the designated exterior perimeter of the enclosed sidewalk cafe. However, fire exit doors that are used exclusively as emergency fire exit doors shall be exempt from this provision. - Fixtures
The furnishings of the interior of an enclosed sidewalk cafe shall consist solely of moveable tables, chairs and decorative accessories. No objects, except lighting fixtures and HVAC installations, may be permanently affixed onto any portion of the wall of the enclosed sidewalk cafe. In no event shall such objects penetrate the exterior perimeter of the wall or the roof of the enclosed sidewalk cafe or impede the transparency as required by this Chapter. The exhaust for such HVAC installations on the adjacent walls shall not be less than 10 feet above curb level. - Refuse storage area
No structure or enclosure to accommodate the storage of garbage may be erected or placed adjacent to or separate from the enclosed sidewalk cafe on the public right-of-way.
Related Code Sections
3307.6.1 Safeguards During Construction or Demolition, Sidewalk Shed Required
When a sidewalk shed is required for the construction or alteration of a structure, the work shall stop at a height of 40 feet (12 192 mm) unless ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3307 Protection of Pedestrians > 3307.6 Sidewalk Sheds > 3307.6.1 Sidewalk Shed Required
3307.6 Safeguards During Construction or Demolition, Sidewalk Sheds
is not required along the edge of the sidewalk shed that abuts a building or structure. A parapet is not required along the edge of a sidewalk shed that abuts ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3307 Protection of Pedestrians > 3307.6 Sidewalk Sheds
3307.6 Safeguards During Construction or Demolition, Sidewalk Sheds
of the sidewalk shed that abuts a building
or structure.
A parapet is not required along the edge of a sidewalk shed that abuts an area that
is closed ...
NYC Building Code 2022 > 33 Safeguards During Construction or Demolition > 3307 Protection of Pedestrians > 3307.6 Sidewalk Sheds
Section 3110 Special Construction, Sidewalk Cafés
Sidewalk cafés provided beyond the building line shall comply with the requirements of this section, the New York City Zoning Resolution ...
Section 3111 Special Construction, Sidewalk Cafés
Sidewalk cafés provided beyond the building line shall comply with the requirements of this section, the New York City Zoning Resolution ...