Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

Section 1614 Structural Integrity Definitions

NYC Building Code 2014 > 16 Structural Design > 1614 Structural Integrity Definitions
JUMP TO FULL CODE CHAPTER
buildings bulletin
Linked Resources Available

This section has been clarified by a buildings bulletin issued by the Department of Buildings.

Learn more in the Linked Resources panel on the right.

1614.1 Definitions

buildings bulletin
Linked Resources Available

This section has been clarified by a buildings bulletin issued by the Department of Buildings.

Learn more in the Linked Resources panel on the right.
The following words and terms shall, for the purposes of this section, have the meanings shown herein.

ALTERNATE LOAD PATH. A secondary or redundant load path capable of transferring the load from one structural element to other structural elements.

ALTERNATE LOAD PATH METHOD. A design approach that accounts for an extreme event by providing alternate load paths for elements that are no longer able to carry load. In an alternate load path design, key elements are considered notionally removed, one at a time, and the structure is designed to transfer the loads from the removed element to other structural elements, as required by Section 1616.

ASPECT RATIO. The height of any portion of a building divided by its least dimension at the elevation from which the height is being measured.

COLLAPSE. Failure of a structural element to the extent that it can no longer support any load.

ELEMENT. A structural member or structural assembly.

KEY ELEMENT. An element of the structural system, including its connections, that meets one or more of the following criteria:
  1. An element which when lost, results in more than local collapse.
  2. An element that braces a key element, the failure of which results in failure of the key element (further secondary elements need not be considered key elements).
  3. An element whose tributary area exceeds 3,000 square feet (279 m2) on a single level.
LOCAL COLLAPSE. Failure of a structural element that results in the collapse of areas being directly supported by that element and not extending vertically more than three stories.

RESPONSE RATIO. The ratio of an ultimate response quantity (e.g., deflection) to its value at yield.

ROTATION. The angle, measured at the ends of a member, whose tangent is equal to the deflection of the member at midspan divided by half the length of the member.

SPECIFIC LOCAL LOAD. A load applied to a structural element or structural system as specified in Section 1616.7.

SPECIFIC LOCAL RESISTANCE METHOD. A design approach that accounts for extreme event loads by providing sufficient strength for elements that may fail. In a specific local resistance design, key elements are designed for specific local loads as required by Section 1616.

Related Code Sections


Section 1614 Structural Design, Structural Integrity Definitions
or redundant load path capable of transferring the load from one structural element to other structural elements. ALTERNATE LOAD PATH METHOD. A design ...
NYC Building Code 2014 > 16 Structural Design > 1614 Structural Integrity Definitions
Section 1615 Structural Design, Structural Integrity Definitions
The following terms are defined in Chapter 2: ALTERNATE LOAD PATH. ALTERNATE LOAD PATH METHOD. ASPECT RATIO. COLLAPSE (STRUCTURAL ...
NYC Building Code 2022 > 16 Structural Design > 1615 Structural Integrity Definitions
Section 1624 Structural Design, Structural Integrity Definitions
secondary or redundant load path capable of transferring the load from one structural element to other structural elements. ALTERNATE LOAD PATH ...
NYC Building Code 2008 > 16 Structural Design > 1624 Structural Integrity Definitions
Section 1502 Roof Assemblies and Rooftop Structures, Definitions
The following terms are defined in Chapter 2: AGGREGATE. BALLAST. BUILDING-INTEGRATED PHOTOVOLTAIC (BIPV) PRODUCT. BUILT-UP ROOF COVERING ...
NYC Building Code 2022 > 15 Roof Assemblies and Rooftop Structures > 1502 Definitions
3102.2 Special Construction, Definitions
to the membrane or is an integral part of the membrane. This is not a cable-supported structure. MEMBRANE-COVERED CABLE STRUCTURE. A nonpressurized structure ...
NYC Building Code 2008 > 31 Special Construction > 3102 Membrane Structures > 3102.2 Definitions
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING