• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2.0.1 Structural Evaluation Procedure

California Administrative Code 2019 > 6 Seismic Evaluation Procedures for Hospital Buildings > 2 Procedures for Structural Evaluation of Buildings > 2.0 General > 2.0.1 Structural Evaluation Procedure
JUMP TO FULL CODE CHAPTER
  1. The structural evaluation process shall include the following steps:
    1. 1.1 Site visit and data collection;
    2. 1.2 Identification of building type;
    3. 1.3 Completion of evaluation statements in appendix;
    4. 1.4 Follow-up field work, if required;
    5. 1.5 Follow-up analysis for "False" evaluation statements;
    6. 1.6 Final evaluation for the building;
    7. 1.7 Preparation of the evaluation report; and
    8. 1.8 Submittal of evaluation report to OSHPD.
  2. A general acute care hospital facility building may be exempted from a structural evaluation upon submittal of a written statement by the hospital owner to OSHPD certifying the following conditions:
    1. 2.1 A conforming building as defined in Article 1, Section 1.2, may be placed into SPC 5 in accordance with Table 2.5.3 under the following circumstances:
      1. The building was designed and constructed to the 1989 or later edition of Part 2, Title 24, and
      2. If any portion of the structure, except for the penthouse, is of steel moment resisting frame construction (Building Type 3, or Building Type 4 or 6 with dual lateral system, as defined in Section 2.2.3) and the building permit was issued after October 25, 1994.
    2. 2.2 All other conforming buildings as defined in Article 1, Section 1.2, may be placed into SPC 4 in accordance with Table 2.5.3, except those required by Section 4.2.10 to be placed in SPC 3 in accordance with Table 2.5.3, without the need for any structural evaluation.
    3. 2.3 Nonconforming buildings as defined in Article 1, Section 1.2 may be placed into SPC 1 in accordance with Table 2.5.3 without any structural evaluation.

Related Code Sections


2.0.1 Seismic Evaluation Procedures for Hospital Buildings, Structural Evaluation Procedure
The structural evaluation process shall include the following steps: 1.1 Site visit and data collection; 1.2 Identification of building type; 1.3 ...
California Administrative Code 2016 > 6 Seismic Evaluation Procedures for Hospital Buildings > 2 Procedures for Structural Evaluation of Buildings > 2.0 General > 2.0.1 Structural Evaluation Procedure
2.0.1 Seismic Evaluation Procedures for Hospital Buildings, Structural Evaluation Procedure
The structural evaluation process shall include the following steps: 1.1 Site visit and data collection; 1.2 Identification of building type ...
California Administrative Code 2019 > 6 Seismic Evaluation Procedures for Hospital Buildings > 2 Procedures for Structural Evaluation of Buildings > 2.0 General > 2.0.1 Structural Evaluation Procedure
2.0.1 Seismic Evaluation Procedures for Hospital Buildings, Structural Evaluation Procedure
The structural evaluation process shall include the following steps: Site visit and data collection; Identification of building type ...
California Administrative Code 2022 > 6 Seismic Evaluation Procedures for Hospital Buildings > 2 Procedures for Structural Evaluation of Buildings > 2.0 General > 2.0.1 Structural Evaluation Procedure
3107F.1.1 [SLC] Marine Oil Terminals, Purpose
This section establishes the minimum performance standards for structural components. Evaluation procedures for seismic performance, strength ...
California Building Code 2016 (Vol 1 & 2) > 31F [SLC] Marine Oil Terminals > 3107F Structural Analysis and Design of Components > 3107F.1 General > 3107F.1.1 Purpose
2.5 Seismic Evaluation Procedures for Hospital Buildings, Final Evaluation
completion of the procedures given in Articles 3 through 10, the evaluator shall assemble and review the results ...
California Administrative Code 2022 > 6 Seismic Evaluation Procedures for Hospital Buildings > 2 Procedures for Structural Evaluation of Buildings > 2.5 Final Evaluation
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING