1620.1 Structural Component Design and Detailing
JUMP TO FULL CODE CHAPTER
The design and detailing of the components of the seismic-force-resisting system shall comply with the requirements of Section 9.5.2.6 of ASCE 7 in addition to the nonseismic requirements of this code except as modified in Sections 1620.1.1, 1620.1.2 and 1620.1.3.
Exception: For structures designed using the simplified analysis procedure in Section 1617.5, the provisions of Sections 1620.2 through 1620.5 shall be used.
Section 9.5.2.6.2.5 of ASCE 7 shall not apply.
Modify ASCE 7, Section 9.5.2.6.2.11, to read as follows:
9.5.2.6.2.11 Elements supporting discontinuous walls or frames. Columns, beams, trusses or slabs supporting discontinuous walls or frames of structures and the connections of the discontinuous element to the supporting member having plan irregularity Type 4 of Table 9.5.2.3.2 or vertical irregularity Type 4 of Table 9.5.2.3.3 shall have the design strength to resist the maximum axial force that can develop in accordance with the special seismic loads of Section 9.5.2.7.1.
9.5.2.6.2.11 Elements supporting discontinuous walls or frames. Columns, beams, trusses or slabs supporting discontinuous walls or frames of structures and the connections of the discontinuous element to the supporting member having plan irregularity Type 4 of Table 9.5.2.3.2 or vertical irregularity Type 4 of Table 9.5.2.3.3 shall have the design strength to resist the maximum axial force that can develop in accordance with the special seismic loads of Section 9.5.2.7.1.
Exceptions:
- The quantity E in Section 9.5.2.7.1 need not exceed the maximum force that can be transmitted to the element by the lateral-force-resisting system at yield.
- Concrete slabs supporting light-framed walls.
Modify ASCE 7, Section 9.5.2.6.3, to read as follows:
9.5.2.6.3 Seismic Design Category C. Structures assigned to Category C shall conform to the requirements of Section 9.5.2.6.2 for Category B and to the requirements of this section. Structures that have plan structural irregularity Type 1a or 1b of Table 9.5.2.3.2 along both principal plan axes, or plan structural irregularity Type 5 of Table 9.5.2.3.2, shall be analyzed for seismic forces in compliance with Section 9.5.2.5.2.2. When the square root of the sum of the squares method of combining directional effects is used,each term computed shall be assigned the sign that will yield the most conservative result.
The orthogonal combination procedure of Section 9.5.2.5.2.2, Item a, shall be required for any column or wall that forms part of two or more intersecting seismic-force-resisting systems and is subjected to axial load due to seismic forces acting along either principal plan axis equaling or exceeding 20 percent of the axial load design strength of the column or wall.
9.5.2.6.3 Seismic Design Category C. Structures assigned to Category C shall conform to the requirements of Section 9.5.2.6.2 for Category B and to the requirements of this section. Structures that have plan structural irregularity Type 1a or 1b of Table 9.5.2.3.2 along both principal plan axes, or plan structural irregularity Type 5 of Table 9.5.2.3.2, shall be analyzed for seismic forces in compliance with Section 9.5.2.5.2.2. When the square root of the sum of the squares method of combining directional effects is used,each term computed shall be assigned the sign that will yield the most conservative result.
The orthogonal combination procedure of Section 9.5.2.5.2.2, Item a, shall be required for any column or wall that forms part of two or more intersecting seismic-force-resisting systems and is subjected to axial load due to seismic forces acting along either principal plan axis equaling or exceeding 20 percent of the axial load design strength of the column or wall.
Related Code Sections
1620.1 Structural Design, Structural Component Design and Detailing
The design and detailing of the components of the seismic-force-resisting system shall comply with the requirements of Section 9.5.2.6 ...
NYC Building Code 2008 > 16 Structural Design > 1620 Earthquake Loads — Design, Detailing Requirements and Structural Component Load Effects > 1620.1 Structural Component Design and Detailing
1620.2.10 Structural Design, Direction of Seismic Load
component. The requirement will be deemed satisfied if the design seismic forces are applied separately and independently in each of the two orthogonal ...
NYC Building Code 2008 > 16 Structural Design > 1620 Earthquake Loads — Design, Detailing Requirements and Structural Component Load Effects > 1620.2 Structural Component Design and Detailing (For Use in the Simplified Analysis Procedure of Section 1617.5) > 1620.2.10 Direction of Seismic Load
1620.2.1 Structural Design, Second-Order Load Effects
Where è exceeds 0.10 as determined in Section 9.5.5.7.2 in ASCE 7, second-order load effects shall be included in the evaluation of component ...
NYC Building Code 2008 > 16 Structural Design > 1620 Earthquake Loads — Design, Detailing Requirements and Structural Component Load Effects > 1620.2 Structural Component Design and Detailing (For Use in the Simplified Analysis Procedure of Section 1617.5) > 1620.2.1 Second-Order Load Effects
1620.2.2 Structural Design, Openings
Where openings occur in shear walls, diaphragms or other plate-type elements, reinforcement at the edges of the openings shall be designed ...
NYC Building Code 2008 > 16 Structural Design > 1620 Earthquake Loads — Design, Detailing Requirements and Structural Component Load Effects > 1620.2 Structural Component Design and Detailing (For Use in the Simplified Analysis Procedure of Section 1617.5) > 1620.2.2 Openings
1620.2.3 Structural Design, Discontinuities in Vertical System
Structures with a discontinuity in lateral capacity, vertical irregularity Type 5, as defined in Table 1616.5.1.2, shall not be over two ...
NYC Building Code 2008 > 16 Structural Design > 1620 Earthquake Loads — Design, Detailing Requirements and Structural Component Load Effects > 1620.2 Structural Component Design and Detailing (For Use in the Simplified Analysis Procedure of Section 1617.5) > 1620.2.3 Discontinuities in Vertical System