Section AK103 Structural-Borne Sound
JUMP TO FULL CODE CHAPTER
Floor/ceiling assemblies between dwelling units, or between a dwelling unit and a public or service area within a structure, shall have an impact insulation class (IIC) rating of not less than 45 when tested in accordance with ASTM E492.
Related Code Sections
1206.3 Interior Environment, Structure-Borne Sound
within the structure shall have an impact insulation class rating of not less than 50, or not less than 45 if field tested, where tested in accordance ...
Building Code of Clark County > 12 Interior Environment > 1206 Sound Transmission > 1206.3 Structure-Borne Sound
Section AK103 Sound Transmission, Structural-Borne Sound
Floor/ceiling assemblies between dwelling units , or between a dwelling unit and a public or service area within a structure, shall have an impact ...