• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2101.2.2 Strength Design

Building Code 2012 of South Holland > 21 Masonry > 2101 General > 2101.2 Design Methods > 2101.2.2 Strength Design
JUMP TO FULL CODE CHAPTER
Masonry designed by the strength design method shall comply with the provisions of Sections 2106 and 2108, except that autoclaved aerated concrete (AAC) masonry shall comply with the provisions of Section 2106 and Chapters 1 and 8 of TMS 402/ACI 530/ASCE 5.

Related Code Sections


2101.2.2 Masonry, Strength Design
Masonry designed by the strength design method shall comply with the provisions of Sections 2106 and 2108, except that autoclaved aerated concrete ...
Building Code 2012 of South Holland > 21 Masonry > 2101 General > 2101.2 Design Methods > 2101.2.2 Strength Design
Section 2108 Masonry, Strength Design of Masonry
The design of masonry structures using strength design shall comply with Section 2106 and the requirements of Chapters 1 through 7 and Chapter 9 ...
Building Code 2018 of South Holland > 21 Masonry > 2108 Strength Design of Masonry
Section 2108 Masonry, Strength Design of Masonry
The design of masonry structures using strength design shall comply with Section 2106 and the requirements of Chapters 1 and 3 of TMS 402/ACI 530 ...
Building Code 2012 of South Holland > 21 Masonry > 2108 Strength Design of Masonry
Section 1909 Concrete, Anchorage to Concrete — Strength Design
The provisions of this section shall govern the strength design of anchors installed in concrete for purposes of transmitting structural loads from ...
Building Code 2012 of South Holland > 19 Concrete > 1909 Anchorage to Concrete — Strength Design
22.2.2.1 Sectional Strength,
Maximum strain at the extreme concrete compression fiber shall be assumed equal to 0.003 ...
Building Code Requirements for Structural Concrete of South Holland > 22 Sectional Strength > 22.2 Design Assumptions for Moment and Axial Strength > 22.2.2 Design Assumptions for Concrete > 22.2.2.1
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING