42-485 Streetscape Provisions
JUMP TO FULL CODE CHAPTER
For the purposes of applying the special "ground floor level" streetscape provisions set forth in Section 37-30 to this Section, narrow streets with a street frontage of 50 feet or more shall be considered "primary street frontages", as defined in Section 37-311.
On narrow streets, for zoning lots with street frontage of 50 feet or more, ground floor uses limited to Use Groups 6A, 6C, 7B, 8A, 8B, 9A, 10A, 12A and 12B shall extend along a minimum of 50 percent of the width of the street frontage of the zoning lot. Such uses shall extend to a depth in accordance with the provisions of Section 37-32 (Ground Floor Depth Requirements for Certain Uses). The remainder of the street frontage of the zoning lot may be occupied by any permitted uses, lobbies or entrances to parking spaces, provided that lobbies shall comply with the provisions for Type 2 lobbies set forth in Section 37-33 (Maximum Width of Certain Uses).
Enclosed parking spaces, or parking spaces covered by a building, including such spaces accessory to residences, shall be permitted to occupy the ground floor, provided that such spaces are wrapped by floor area or screened in accordance with the provisions of Section 37-35 (Parking Wrap and Screening Requirements), as applicable.
For any development or enlargement that includes a ground floor street wall, each ground floor street wall occupied by uses listed in Use Groups 1 through 15, not including dwelling units, shall be glazed in accordance with the provisions of Section 37-34 (Minimum Transparency Requirements).
Related Code Sections
102 Application and Administration, Anthropometric Provisions
The technical criteria in this standard are based on adult dimensions and anthropometrics. This standard also contains technical criteria based ...
Accessible and Usable Buildings and Facilities 2009 of New York City > 1 Application and Administration > 102 Anthropometric Provisions
1101.2 Recreational Facilities, Special Provisions
The following shall not be required to be accessible or to be on an accessible route: Raised structures used solely for refereeing, judging ...
Accessible and Usable Buildings and Facilities 2009 of New York City > 11 Recreational Facilities > 1101 General > 1101.2 Special Provisions
Article 1 General Provisions [PDF] (page 1)
ARTICLE 1. GENERAL PROVISIONS (1). §C26-1.0 Short Title.-This title shall be known and may be cited as the “Building Code.” (2). §C26-2.0 Matter ...
Article 1 General Provisions [PDF] (page 2)
Affected.-All provisions of this title shall apply with equal force to municipal and private structures, except as may be otherwise specifically ...
Article 1 Administration and Enforcement, General Provisions
in specific cases by the commissioner, or by the board of standards and appeals, under and pursuant to the provisions of paragraph two of subdivision (b ...