• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

93-562 Street Wall Regulations for Certain Streets

NYC Zoning Resolution > IX - Special Purpose Districts > 3 Special Hudson Yards District (HY) > 93-50 Special Height, Setback and Yard Regulations > 93-56 Special Height and Setback Regulations in Subdistrict F > 93-562 Street Wall Regulations for Certain Streets
JUMP TO FULL CODE CHAPTER
The locations of all street walls identified in this Section are shown on Map 5 (Subdistrict F: Mandatory Street Wall Requirements) in Appendix B.
  1. Applicability

    The provisions of this Section shall apply to:
    1. All street walls of buildings on Site 1 that front along:
      1. the West 32nd Street Extension;
      2. the Western Open Space within 60 feet of the West 32nd Street Extension; and
      3. the Midblock Connection within 60 feet of the West 32nd Street Extension.
    2. All street walls of buildings on Site 2 that front along:
      1. Eleventh Avenue south of the Northeast Plaza;
      2. the West 32nd Street Extension; and
      3. the Midblock Connection within 60 feet of the West 32nd Street Extension.
    3. All street walls of a building on Site 4 that front along:
      1. Eleventh Avenue;
      2. the West 32nd Street Extension within 50 feet of Eleventh Avenue; and
      3. the West 31st Street Extension within 50 feet of Eleventh Avenue.
    4. All street walls of a building on Site 6 that front along:
      1. Eleventh Avenue five feet north of the High Line;
      2. the West 31st Street Extension;
      3. the High Line, completely above the High Line bed;
      4. the Southwest Open Space within 60 feet of the High Line; and
      5. the Southwest Open Space within 60 feet of the West 31st Street Extension.
  2. Street wall location

    All street walls identified in paragraph (a) of this Section shall be located on the street line.

    All such street walls shall extend along the entire street frontage of the site or the required portion identified in paragraph (a). However, such street wall location rules may be modified in accordance with the recess provisions of paragraph (c) of this Section.
  3. Recesses
    1. Ground floor recesses up to three feet deep shall be permitted for access to building entrances;
    2. To allow for corner articulation, the required street wall may be located anywhere within an area bounded by intersecting street lines and lines 15 feet from and parallel to such lines;
    3. To ensure variation in the required street wall, a building shall provide recesses or ground floor level setbacks in accordance with the following provisions:
      1. A minimum of 20 percent of the aggregate width of street walls shall provide a minimum recess of three feet from the street wall above the level of the second story. However, for the portion of Site 6 that fronts along the High Line, such recess shall be provided above the level of the first story. However, no portion of such recess shall be located within 30 feet of the intersection of two street lines, except where corner articulation is provided in accordance with paragraph (c)(2) of this Section.
      2. A maximum of 30 percent, or 50 percent for Site 4, of the aggregate width of street walls may provide a recess of up to 15 feet at any level, which may extend to the height of the building base and may allow for portions of towers to rise without setback from the ground floor level. However, no such setbacks shall be permitted within 30 feet of the intersection of two street lines, except where corner articulation is provided in accordance with paragraph (c)(2) of this Section.

Related Code Sections


§28-102.5 Administration, Regulation of Lots
The regulation of lots, in conformity with the street on which they are situated, shall be calculated at curb level. Where a lot has more than one ...
NYC General Admin. Provisions 2014 > 1 Administration > 102 Applicability > §28-102.5 Regulation of Lots
Article 10 Precautions During Building Operations [PDF] (page 6)
smaller than twenty-five feet by one hundred feet. (9.4.3.1). §C26-563.0 Retaining Walls.a. Retaining Walls to Conform to Street Regulation.-When ...
NYC 1938 Code [PDF] > 10 Precautions During Building Operations
G303.5 Flood-Resistant Construction, Streets and Sidewalks
Streets and sidewalks shall be designed to minimize potential for increasing or aggravating flood levels and shall meet the requirements of Section ...
NYC Building Code 2014 > G Flood-Resistant Construction > G303 Site Improvement > G303.5 Streets and Sidewalks
G303.5 Flood-Resistant Construction, Streets and Sidewalks
Streets and sidewalks shall be designed to minimize potential for increasing or aggravating flood levels and shall meet the requirements of Section ...
NYC Building Code 2008 > G Flood-Resistant Construction > G303 Site Improvement > G303.5 Streets and Sidewalks
G303.6 Flood-Resistant Construction, Streets and Sidewalks
Streets and sidewalks shall be designed to minimize potential for increasing or aggravating flood levels and shall meet the requirements of Section ...
NYC Building Code 2022 > G Flood-Resistant Construction > G303 Site Improvement > G303.6 Streets and Sidewalks
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING