Storefronts in buildings developed after February 3, 1977, in portions of buildings located on the ground floor that are enlarged after February 3, 1977, and any existing storefronts that are altered, shall comply with the following standards:
  1. show windows shall have a sill height of not more than 2 feet, 6 inches above curb level and extend to a maximum height of between eight feet and 10 feet above curb level;
  2. the storefront shall have transparent areas no more than 10 feet in width, measured horizontally, and which transparent areas shall be separated by a mullion of no less than six inches in width; and
  3. storefront entrance doors shall be set back a minimum of two feet behind the vertical surface of the show windows.
STOREFRONT ILLUSTRATION

Related Code Sections

3301.10 Safeguards During Construction or Demolition, Obscured Lawful Signs
the structure is adjacent to any building and obscures from view a lawful and existing sign. The temporary sign shall comply with the following requirements ...
3301.10 Safeguards During Construction or Demolition, Obscured Lawful Signs
the structure is adjacent to any building and obscures from view a lawful and existing sign. The temporary sign shall comply with the following requirements ...
§28-112.2 Administration, Schedule of Permit Fees
Permits for new buildings, structures, mechanical, and plumbing systems or alterations requiring a permit shall be accompanied by a fee for each ...
§27-731 Light, Heat, Ventilation and Noise Control, Alterations
No building, or part thereof, shall hereafter be altered or rearranged so as to reduce any of the following to less than the required standards ...
3301.9.6 Safeguards During Construction or Demolition, Obscured Lawful Signs
When a protective structure constructed in accordance with Section 3307 obscures from view a lawful and existing sign, a temporary sign may be posted ...