• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

69.5.3.5 Storage Within Residential Buildings

Fire Code 2018 of West Virginia > 69 Liquefied Petroleum Gases and Liquefied Natural Gases > 69.5 Storage of Cylinders Awaiting Use, Resale, or Exchange > 69.5.3 Storage Within Buildings > 69.5.3.5 Storage Within Residential Buildings
JUMP TO FULL CODE CHAPTER
Storage of cylinders within a residential building, including the basement or any storage area in a common basement of a multiple-family building and attached or detached garages, shall be limited to cylinders each with a maximum water capacity of 2.7 lb (1.2 kg) and shall not exceed 5.4 lb (2.4 kg) aggregate water capacity per each living space unit. [58:8.3.5]

Related Code Sections


69.5.3.5 Liquefied Petroleum Gases and Liquefied Natural Gases, Storage Within Residential Buildings
Storage of cylinders within a residential building, including the basement or any storage area in a common basement of a multiple-family building ...
Fire Code 2018 of West Virginia > 69 Liquefied Petroleum Gases and Liquefied Natural Gases > 69.5 Storage of Cylinders Awaiting Use, Resale, or Exchange > 69.5.3 Storage Within Buildings > 69.5.3.5 Storage Within Residential Buildings
808.3 Alterations - Level 2, Residential Occupancies
In Group R-2, R-3 and R-4 occupancies and buildings regulated by the International Residential Code , the requirements of Sections 808.3.1 through ...
Existing Building Code 2015 of West Virginia > 8 Alterations - Level 2 > 808 Electrical > 808.3 Residential Occupancies
60.4.2.1.8 Hazardous Materials, Residential Occupancies
The MAQ of hazardous materials per control area in residential occupancies, including lodging and rooming houses, hotels, dormitories, apartments ...
Fire Code 2018 of West Virginia > 60 Hazardous Materials > 60.4 Permissible Storage and Use Locations > 60.4.2 Control Areas > 60.4.2.1 > 60.4.2.1.8 Residential Occupancies
6.1.8 Classification of Occupancy, Residential
: 6.1.8.1] A building that contains not more than ...
Fire Code 2018 of West Virginia > 6 Classification of Occupancy > 6.1 Classification of Occupancy > 6.1.8 Residential
52.3.2.1.3 Energy Storage Systems, Separation
of the building as stated in 52.3.2.1.3.1 and 52.3.2.1.3.2. Stationary storage battery systems shall be allowed to be in the same room with the equipment ...
Fire Code 2018 of West Virginia > 52 Energy Storage Systems > 52.3* Additional Battery Technologies > 52.3.2* Stationary Storage Battery Systems > 52.3.2.1 Location and Occupancy Separation > 52.3.2.1.3 Separation
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING