1705.12.7 Storage Racks
JUMP TO FULL CODE CHAPTER
Periodic special inspection is required for the anchorage of storage racks that are 8 feet (2438 mm) or greater in height in structures assigned to Seismic Design Category D, E or F.
Related Code Sections
17.4.1.2 Installation Requirements for Hanging and Support of System Piping, Storage Racks
Where sprinkler piping is installed in storage racks, piping shall be supported from the storage rack structure or building in accordance with all ...
Standard for the Installation of Sprinkler Systems 2019 of Illinois > 17 Installation Requirements for Hanging and Support of System Piping > 17.4* Installation of Pipe Hangers > 17.4.1 General > 17.4.1.2 Storage Racks
1705.12.7 Special Inspections and Tests, Storage Racks
Periodic special inspection is required for the anchorage of storage racks that are 8 feet (2438 mm) or greater in height in structures assigned ...
Building Code 2018 of Illinois > 17 Special Inspections and Tests > 1705 Required Special Inspections and Tests > 1705.12 Special Inspections for Seismic Resistance > 1705.12.7 Storage Racks
1705.13.7 Special Inspections and Tests, Storage Racks
Steel storage racks and steel cantilevered storage racks that are 8 feet (2438 mm) in height or greater and assigned to Seismic Design ...
Building Code 2021 of Illinois > 17 Special Inspections and Tests > 1705 Required Special Inspections and Tests > 1705.13 Special Inspections for Seismic Resistance > 1705.13.7 Storage Racks
2209.1 Steel, Storage Racks
The design, testing and utilization of storage racks made of cold-formed or hot-rolled steel structural members shall be in accordance with RMI ...
Section 2209 Steel, Steel Storage Racks
The design, testing and utilization of steel storage racks made of cold-formed or hot-rolled steel structural members shall ...