Material shall not be stored on catch platforms, working platforms, floors, or stairways of any structure, except that any one floor of a building to be demolished may be used for the temporary storage of material when such floor can be evaluated by a registered design professional and proven to be of adequate strength to support one and one-half times the load to be superimposed. Such evaluation by the registered design professional shall be maintained by the permit holder and made available to the department upon request.
3306.9.11.1 Avoid Interference
Storage spaces shall not interfere with access to any stairway or passageway, and suitable barricades shall be provided so as to prevent material from sliding or rebounding into any space accessible to the public. All material shall be safely stored or piled in such storage locations in a manner that will not overload any part of the structure or create any hazard.
3306.9.11.2 Examination of Connections
Before any material is stored on any floor, the existing flooring adjacent to bearing walls, shear walls, beams and columns shall be removed and the connections of the floor framing system to the bearing walls, shear walls, beams and columns shall be carefully examined by a competent person designated by the permit holder to ascertain their condition and adequacy to support such material. If the connections are found to be in poor condition or inadequate to support the stored material, no material shall be deposited on the floor until these connections are shored from the cellar floor through each successive floor or otherwise strengthened to safely support such material.
3306.9.11.3 Removal of Floor Slabs for Storage
In buildings of noncombustible construction, floor slabs to an elevation of not more than 25 feet (7620 mm) above the legally established curb level may be removed to provide temporary storage for debris, provided that:
  1. The stored debris is piled with sufficient uniformity to prevent lateral displacement of interior walls or columns as determined by a registered design professional.
  2. The height of the piled material will not burst the exterior walls due to horizontal loading as determined by a registered design professional.
  3. The operation does not otherwise endanger the stability of the structure.
3306.9.11.4 Cellar or Basement Storage
Debris stored in the cellar or basement shall not be piled above the level of the adjacent exterior grade unless the demolition contractor provides sheet-piling, shoring, bracing, or such other means necessary to insure the stability of the walls and to prevent any wall from collapsing due to horizontal loading created by the debris as determined by a registered design professional. Where debris is stored against a party wall, the requirements of Section 3306.9.11.5 shall also apply.
3306.9.11.5 Examination of Party Walls
Party walls shall be carefully examined by a competent person designated by the permit holder to ascertain the condition and adequacy of the party wall prior to the placement of any material that will impose a load upon such party wall. If the party wall is to be found to be in poor condition or inadequate to support the stored material, no material shall be deposited on the floor until the party wall is shored or otherwise strengthened as determined by a registered design professional to safely support such material.

Related Code Sections

1903.7 Concrete, Storage of Materials
The storage of materials for use in concrete shall comply with the provisions of Sections 1903.7.1 and 1903.7.2 ...
1903.7 Concrete, Storage of Materials
The storage of materials for use in concrete shall comply with ACI 318, Section 3.7, and the provisions of Sections 1903.7.1 and 1903.7.2 ...
1903.8 Concrete, Storage of Materials
The storage of materials for use in concrete shall comply with ACI 318, Section 26.5.1, and the provisions of Sections 1903.8.1 and 1903.8.2 ...
3306.9.11 Safeguards During Construction or Demolition, Storage of Material
to be demolished may be used for the temporary storage of material when such floor can be evaluated by a registered design professional and proven ...
3306.9.11 Safeguards During Construction or Demolition, Storage of Material
to be demolished may be used for the temporary storage of material when such floor can be evaluated by a registered design professional and proven ...