• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

(J) Section 3310 Storage of Fireworks at Exhibition Site

Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks > 3310 Storage of Fireworks at Exhibition Site
JUMP TO FULL CODE CHAPTER

(1) 3310.1 Storage

The storage of fireworks at the exhibition site shall comply with the requirements of this paragraph and NFPA 1123 and NFPA 1126 as listed in rule 1301:7-7-47 of the Administrative Code. All 1.3G fireworks to be used at a fireworks exhibition shall be stored in an approved magazine at the exhibition site until immediately prior to their use. Such magazine shall be located in an area approved by the local fire official and shall meet the table of distances requirements of this rule. Magazines shall be constructed in accordance with this rule. No fireworks may be acquired or stored by an exhibitor until the permit for the specific exhibition that the fireworks will be used at has been issued. Such storage shall not exceed a period of seventy-two hours prior to the start of the fireworks exhibition as provided for in the approved permit unless all of the following apply:

(a) The fire code official having jurisdiction over the exhibition approves the extended time period for storage as part of the exhibition permit.

(b) All fireworks are stored at the exhibition site as that site is described in the permit.

(c) The fireworks stored at the exhibition site in accordance with this rule shall only be those fireworks approved by the fire code official having jurisdiction as necessary for the specific exhibition listed in the exhibition permit that describes the extended storage period.

(d) The extended time period for storage shall not exceed a maximum of fourteen days.

(2) 3310.2 Supervision and Weather Protection

Beginning as soon as fireworks have been delivered to the exhibition site, they shall not be left unattended.

(3) 3310.3 Weather Protection

Fireworks shall be kept dry after delivery to the exhibition site.

(4) 3310.4 Inspection

Fireworks shall be inspected by the operator or assistants after delivery to the exhibition site. Fireworks having tears, leaks, broken fuses or signs of having been wet shall be set aside and shall not be fired. Aerial shells shall be checked for proper fit in mortars prior to discharge. Aerial shells that do not fit properly shall not be fired. After the fireworks exhibition, damaged, deteriorated or dud fireworks shall either be returned to the supplier or destroyed in accordance with the supplier's instructions and paragraph (D)(10)(3304.10) of this rule.

Exception: Minor repairs to fuses shall be allowed. For electrically ignited exhibitions, attachment of electric matches and similar tasks shall be allowed.

(5) 3310.5 Sorting and Separation

After delivery to the exhibition site and prior to the fireworks exhibition, all aerial shells shall be separated according to size and their designation as salutes.

Exception: For electrically fired fireworks exhibitions, or exhibitions where all shells are loaded into mortars prior to the show, there is no requirement for separation of shells according to size or their designation as salutes.

(6) 3310.6 Ready Boxes

Fireworks that will be temporarily stored at the site during the fireworks exhibition shall be stored in ready boxes located upwind and at least 25 feet (7620 mm) from the mortar placement and separated according to size and their designation as salutes.

Exception: For electrically fired fireworks exhibitions, or exhibitions where all shells are loaded into mortars prior to the show, there is no requirement for separation of shells according to size, their designation as salutes, or for the use of ready boxes.

Related Code Sections


Section 3310 Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks, Storage of Fireworks at Exhibition Site
The storage of fireworks at the exhibition site shall comply with the requirements of this paragraph and NFPA 1123 and NFPA 1126 as listed in rule ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks > 3310 Storage of Fireworks at Exhibition Site
3310.2 Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks, Supervision and Weather Protection
Beginning as soon as fireworks have been delivered to the exhibition site, they shall not be left unattended ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks > 3310 Storage of Fireworks at Exhibition Site > 3310.2 Supervision and Weather Protection
3308.7.1 Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks,
The manner and place of storage of all fireworks prior to and during the fireworks exhibition for all fireworks storage shall be in accordance ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks > 3308 Fireworks Exhibition > 3308.7 > 3308.7.1
Section 3308 Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks, Fireworks Exhibition
to and during the fireworks exhibition for all fireworks storage shall be in accordance with paragraph (J)(1)(3310.1) of this rule ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks > 3308 Fireworks Exhibition
3308.7 Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks,
The manner and place of storage of all fireworks prior to and during the fireworks exhibition for all fireworks storage shall ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks > 3308 Fireworks Exhibition > 3308.7
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE