Section 607 Storage of Firewood and Combustible Materials
JUMP TO FULL CODE CHAPTER
Firewood and combustible material shall not be stored in unenclosed spaces beneath buildings or structures, or on decks or under eaves, canopies or other projections or overhangs. Where required by the code official, storage of firewood and combustible material stored in the defensible space shall be located not less than 20 feet (6096 mm) from structures and separated from the crown of trees by a horizontal distance of not less than 15 feet (4572 mm).
Firewood and combustible materials not for consumption on the premises shall be stored so as to not pose a hazard. See Appendix A.
Related Code Sections
Section 607 Fire Protection Requirements, Storage of Firewood and Combustible Materials
or other projections or overhangs. Where required by the code official, storage of firewood and combustible material stored in the defensible space shall ...
Wildland-Urban Interface Code 2021 of Colorado > 6 Fire Protection Requirements > 607 Storage of Firewood and Combustible Materials
Chapter 6 Fire Protection Requirements
include spark arrestors on chimneys and regulated storage of combustible materials, firewood and LP-gas ...
5704.3.5.4 Flammable and Combustible Liquids, Combustible Materials
In areas that are not open to the public, Class I, II and IIIA liquids shall not be stored in the same pile or rack section as ordinary combustible ...
Fire Code 2021 of Colorado > 57 Flammable and Combustible Liquids > 5704 Storage > 5704.3 Container and Portable Tank Storage > 5704.3.5 Storage in Control Areas > 5704.3.5.4 Combustible Materials
5704.3.5.4 Flammable and Combustible Liquids, Combustible Materials
In areas that are not open to the public, Class I, II and IIIA liquids shall not be stored in the same pile or rack section as ordinary combustible ...
Fire Code 2018 of Colorado > 57 Flammable and Combustible Liquids > 5704 Storage > 5704.3 Container and Portable Tank Storage > 5704.3.5 Storage in Control Areas > 5704.3.5.4 Combustible Materials
1207.4.6 Energy Systems, Combustible Storage
Combustible materials shall not be stored in ESS rooms, areas or walk-in units. Combustible materials in occupied work centers covered ...
Fire Code 2021 of Colorado > 12 Energy Systems > 1207 Electrical Energy Storage Systems (ESS) > 1207.4 General Installations Requirements > 1207.4.6 Combustible Storage