• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

63.3.10.3 Storage Configuration

Fire Code 2018 of Maine > 63 Compressed Gases and Cryogenic Fluids > 63.3 Compressed Gases > 63.3.10 Unstable Reactive Gases (Nondetonable) > 63.3.10.3 Storage Configuration
JUMP TO FULL CODE CHAPTER

63.3.10.3.1

Unstable reactive Class 3 compressed gases stored in cylinders, containers, or tanks shall be arranged to limit individual groups of cylinders, containers, or tanks to areas not exceeding 100 ft2 (9.3 m2). [55:7.10.3.1]

63.3.10.3.2

Multiple areas shall be separated by aisles. [55:7.10.3.2]

63.3.10.3.3

Aisle widths shall not be less than the height of the cylinders, containers, or tanks or 4 ft (1.2 m), whichever is greater. [55:7.10.3.3]

Related Code Sections


63.3.10.3 Compressed Gases and Cryogenic Fluids, Storage Configuration
Unstable reactive Class 3 compressed gases stored in cylinders, containers, or tanks shall be arranged to limit individual groups of cylinders ...
Fire Code 2018 of Maine > 63 Compressed Gases and Cryogenic Fluids > 63.3 Compressed Gases > 63.3.10 Unstable Reactive Gases (Nondetonable) > 63.3.10.3 Storage Configuration
34.1.1.1 General Storage,
Storage configurations shall include palletized storage, solid-piled storage, and storage in bin boxes, on shelves, or on racks ...
Fire Code 2018 of Maine > 34 General Storage > 34.1 General > 34.1.1 Application > 34.1.1.1
14.3.6 Protection for Palletized, Solid-Piled, Bin Box, Shelf, or Back-To-Back Shelf Storage of Class I Through Class IV Commodities,
Building steel shall not require special protection where Table 14.3.1 are applied as appropriate for the storage configuration ...
Standard for the Installation of Sprinkler Systems 2016 of Maine > 14 Protection for Palletized, Solid-Piled, Bin Box, Shelf, or Back-To-Back Shelf Storage of Class I Through Class IV Commodities > 14.3 CMSA Sprinklers for Palletized or Solid-Piled Storage of Class I Through Class IV Commodities > 14.3.6
15.3.5 Protection for Palletized, Solid-Piled, Bin Box, Shelf, or Back-To-Back Shelf Storage of Plastic and Rubber Commodities,
Building steel shall not require special protection where Table 15.3.1 is applied as appropriate for the storage configuration ...
Standard for the Installation of Sprinkler Systems 2016 of Maine > 15 Protection for Palletized, Solid-Piled, Bin Box, Shelf, or Back-To-Back Shelf Storage of Plastic and Rubber Commodities > 15.3 CMSA Sprinklers for Palletized or Solid-Piled Storage of Group A Plastic Commodities > 15.3.5
16.2.2.6 Protection of Rack Storage of Class I Through Class IV Commodities,
Building steel shall not require special protection where Table 16.2.2.1 is applied as appropriate for the storage configuration ...
Standard for the Installation of Sprinkler Systems 2016 of Maine > 16 Protection of Rack Storage of Class I Through Class IV Commodities > 16.2 Protection Criteria for Rack Storage of Class I Through Class IV Commodities Stored Up to and Including 25 ft (7.6 m) in Height > 16.2.2 CMSA Sprinklers for Rack Storage of Class I Through Class IV Commodities Stored Up to and Including 25 ft (7.6 m) in Height > 16.2.2.6
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING