1910.263(d)(6)(i)
[Reserved]
1910.263(d)(6)(iii)
Storage bins where the side is more than 5 feet in depth shall be provided with standard stationary safety ladders, both inside and outside, to reach from floor level to top of bin and from top of bin to inside bottom, keeping the ladder end away from the moving screw conveyor.
1910.263(d)(6)(iv)
[Reserved]
1910.263(d)(6)(v)
[Reserved]
1910.263(d)(6)(vi)
The main entrance cover of large storage bins located at the interior exit ladder shall be provided with an electric interlock for motors operating both feed and unloading screw, so that these motors cannot operate while the cover is open.
1910.263(d)(6)(ii)
Storage bins shall be provided with gaskets and locks or latches to keep the cover closed, or other equivalent devices in order to insure the dust tightness of the cover. Covers at openings where an employee may enter the bin shall also be provided with a hasp and a lock, so located that the employee may lock the cover in the open position whenever it is necessary to enter the bin.

Related Code Sections

1910.109(g)(4) Hazardous Materials, Bulk Storage Bins
Bins containing ammonium nitrate shall be separated from blasting agent storage and explosives storage in conformity ...
1910.263(d)(6)(vi) Special Industries,
The main entrance cover of large storage bins located at the interior exit ladder shall be provided with an electric interlock for motors operating ...
1910.109(g)(4)(iii) Hazardous Materials,
Bin loading manways or access hatches shall be hinged or otherwise attached to the bin and be designed to permit locking ...
1910.109(g)(4)(i) Hazardous Materials,
The bin, including supports, shall be constructed of compatible materials, waterproof, and adequately supported and braced to withstand ...