• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

5704.4.2.4 Storage Adjacent to Buildings

Fire Code 2018 of Colorado > 57 Flammable and Combustible Liquids > 5704 Storage > 5704.4 Outdoor Storage of Containers and Portable Tanks > 5704.4.2 Location on Property > 5704.4.2.4 Storage Adjacent to Buildings
JUMP TO FULL CODE CHAPTER
Not more than 1,100 gallons (4163 L) of liquids stored in closed containers and portable tanks is allowed adjacent to a building located on the same premises and under the same management, provided that one of the following requirements is met:
  1. The building does not exceed one story in height. Such building shall be of fire-resistance-rated construction with noncombustible exterior surfaces or noncombustible construction and shall be used principally for the storage of liquids.
  2. The exterior building wall adjacent to the storage area shall have a fire-resistance rating of not less than 2 hours, having no openings to above-grade areas within 10 feet (3048 mm) horizontally of such storage and no openings to below-grade areas within 50 feet (15 240 mm) horizontally of such storage.
The quantity of liquids stored adjacent to a building protected in accordance with Item 2 is allowed to exceed 1,100 gallons (4163 L), provided that the maximum quantity per pile does not exceed 1,100 gallons (4163 L) and each pile is separated by a 10-foot-minimum (3048 mm) clear space along the common wall.
Where the quantity stored exceeds 1,100 gallons (4163 L) adjacent to a building complying with Item 1, or the provisions of Item 1 cannot be met, a minimum distance in accordance with Table 5704.4.2, column 7 ("Minimum Distance to Lot Line of Property That Can Be Built Upon") shall be maintained between buildings and the nearest container or portable tank.

Related Code Sections


5704.4.2.4 Flammable and Combustible Liquids, Storage Adjacent to Buildings
principally for the storage of liquids. The exterior building wall adjacent to the storage area shall have a fire-resistance rating of not less than ...
Fire Code 2021 of Colorado > 57 Flammable and Combustible Liquids > 5704 Storage > 5704.4 Outdoor Storage of Containers and Portable Tanks > 5704.4.2 Location on Property > 5704.4.2.4 Storage Adjacent to Buildings
5704.4.2.4 Flammable and Combustible Liquids, Storage Adjacent to Buildings
principally for the storage of liquids. The exterior building wall adjacent to the storage area shall have a fire-resistance rating of not less than 2 ...
Fire Code 2018 of Colorado > 57 Flammable and Combustible Liquids > 5704 Storage > 5704.4 Outdoor Storage of Containers and Portable Tanks > 5704.4.2 Location on Property > 5704.4.2.4 Storage Adjacent to Buildings
5904.2.1 Flammable Solids, Distance From Storage to Exposures
of the storage area is allowed in lieu of such distance. The wall shall either be an independent structure, or the exterior wall of the building adjacent ...
Fire Code 2021 of Colorado > 59 Flammable Solids > 5904 Storage > 5904.2 Outdoor Storage > 5904.2.1 Distance From Storage to Exposures
5904.2.1 Flammable Solids, Distance From Storage to Exposures
of the storage area is allowed in lieu of such distance. The wall shall either be an independent structure, or the exterior wall of the building adjacent ...
Fire Code 2018 of Colorado > 59 Flammable Solids > 5904 Storage > 5904.2 Outdoor Storage > 5904.2.1 Distance From Storage to Exposures
5404.2.2 Corrosive Materials, Distance From Storage to Exposures
either be an independent structure, or the exterior wall of the building adjacent to the storage area ...
Fire Code 2021 of Colorado > 54 Corrosive Materials > 5404 Storage > 5404.2 Outdoor Storage > 5404.2.2 Distance From Storage to Exposures
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING