[BS] 1405.7 Stone veneer

California Building Code 2016 (Vol 1) > 14 Exterior Walls > 1405 Installation of Wall Coverings > 1405.7 Stone veneer
JUMP TO FULL CODE CHAPTER

Anchored stone veneer units not exceeding 10 inches (254 mm) in thickness shall be anchored directly to masonry, concrete or to stud construction by one of the following methods:

  1. With concrete or masonry backing, anchor ties shall be not less than 0.1055-inch (2.68 mm) corrosion-resistant wire, or approved equal, formed beyond the base of the backing. The legs of the loops shall be not less than 6 inches (152 mm) in length bent at right angles and laid in the mortar joint, and spaced so that the eyes or loops are 12 inches (305 mm) maximum on center in both directions. There shall be provided not less than a 0.1055-inch (2.68 mm) corrosion-resistant wire tie, or approved equal, threaded through the exposed loops for every 2 square feet (0.2 m2) of stone veneer. This tie shall be a loop having legs not less than 15 inches (381 mm) in length bent so that the tie will lie in the stone veneer mortar joint. The last 2 inches (51 mm) of each wire leg shall have a right-angle bend. One-inch (25 mm) minimum thickness of cement grout shall be placed between the backing and the stone veneer.
  2. With wood stud backing, a 2-inch by 2-inch (51 by 51 mm) 0.0625-inch (1.59 mm) zinc-coated or nonmetallic coated wire mesh with two layers of water-resistive barrier in accordance with Section 1404.2 shall be applied directly to wood studs spaced not more than 16 inches (406 mm) on center. On studs, the mesh shall be attached with 2-inch-long (51 mm) corrosion-resistant steel wire furring nails at 4 inches (102 mm) on center providing a minimum 1.125-inch (29 mm) penetration into each stud and with 8d annular threaded nails at 8 inches (203 mm) on center. into top and bottom plates or with equivalent wire ties. There shall be not less than a 0.1055-inch (2.68 mm) zinc-coated or nonmetallic coated wire, or approved equal, attached to the stud with not smaller than an 8d (0.120 in. diameter) annular threaded nail for every 2 square feet (0.2 m2) of stone veneer. This tie shall be a loop having legs not less than 15 inches (381 mm) in length, so bent that the tie will lie in the stone veneer mortar joint. The last 2 inches (51 mm) of each wire leg shall have a right-angle bend. One-inch (25 mm) minimum thickness of cement grout shall be placed between the backing and the stone veneer.
  3. With cold-formed steel stud backing, a 2-inch by 2-inch (51 by 51 mm) 0.0625-inch (1.59 mm) zinc-coated or nonmetallic coated wire mesh with two layers of water-resistive barrier in accordance with Section 1404.2 shall be applied directly to steel studs spaced a not more than 16 inches (406 mm) on center. The mesh shall be attached with corrosion-resistant #8 self-drilling, tapping screws at 4 inches (102 mm) on center, and at 8 inches (203 mm) on center into top and bottom tracks or with equivalent wire ties. Screws shall extend through the steel connection not fewer than three exposed threads. There shall be not less than a 0.1055-inch (2.68 mm) corrosion-resistant wire, or approved equal, attached to the stud with not smaller than a #8 self-drilling, tapping screw extending through the steel framing not fewer than three exposed threads for every 2 square feet (0.2 m2) of stone veneer. This tie shall be a loop having legs not less than 15 inches (381 mm) in length, so bent that the tie will lie in the stone veneer mortar joint. The last 2 inches (51 mm) of each wire leg shall have a right-angle bend. One-inch (25 mm) minimum thickness of cement grout shall be placed between the backing and the stone veneer. The cold-formed steel framing members shall have a minimum bare steel thickness of 0.0428 inches (1.087 mm).
Share URL

Copy and paste the link below into emails, chats or browsers.

Copy

You can also copy or bookmark the link from your browser's address bar.

Related Code Sections


1404.7 Exterior Walls, Stone veneer
Anchored stone veneer units not exceeding 10 inches (254 mm) in thickness shall be anchored directly to masonry, concrete or to stud construction ...
California Building Code 2019 (Vol 1 & 2) > 14 Exterior Walls > 1404 Installation of Wall Coverings > 1404.7 Stone veneer
1405.7 Exterior Walls, Stone veneer
Anchored stone veneer units not exceeding 10 inches (254 mm) in thickness shall be anchored directly to masonry, concrete or to stud construction ...
California Building Code 2016 (Vol 1) > 14 Exterior Walls > 1405 Installation of Wall Coverings > 1405.7 Stone veneer
10.1.5.1 Seismic Evaluation Procedures for Hospital Buildings, Thin stone veneer panels
Stone anchorages are adequate for computed loads. For conforming buildings, the evaluator may consider this condition as mitigated ...
California Administrative Code 2016 > 6 Seismic Evaluation Procedures for Hospital Buildings > 10 Evaluation of Elements That Are Not Part of the Lateral-Force-Resisting System > 10.1 Nonstructural walls > 10.1.5 Other veneer/panel systems > 10.1.5.1 Thin stone veneer panels
R301.2.2.2.2 Building Planning, Stone and masonry veneer
Anchored stone and masonry veneer shall comply with the requirements of Sections R702.1 and R703 ...
California Residential Code 2016 > 3 Building Planning > R301 Design Criteria > R301.2 Climatic and geographic design criteria > R301.2.2 Seismic provisions > R301.2.2.2 Seismic Design Category C > R301.2.2.2.2 Stone and masonry veneer
R301.2.2.3 Building Planning, Stone and masonry veneer
Anchored stone and masonry veneer shall comply with the requirements of Sections R702.1 and R703 ...
California Residential Code 2019 > 3 Building Planning > R301 Design Criteria > R301.2 Climatic and geographic design criteria > R301.2.2 Seismic provisions > R301.2.2.3 Stone and masonry veneer
About UpCodes

UpCodes provides an intuitive resource to navigate building regulations.

Codes are organized by jurisdiction to help you understand which regulations apply to your project.


Find Your Codes
COMPANY INFO About Free Law Contact Careers Terms Privacy Press Kit
CATEGORY General New York City New York State California Codes Building Codes Online
PREMIUM Features Pricing Sign Up Log In
CODES IBC 2015 IRC 2015 IPC 2015 California Building Code 2016 Popular Sections

FOLLOW US