A solid and continuous stripe shall be applied to the horizontal leading edge of each step and shall extend for the full length of the step. Outlining stripes shall have a minimum horizontal width of 1 inch (25 mm) and a maximum width of 2 inches (51 mm). The leading edge of the stripe shall be placed not more than 1/2 inch (12.7 mm) from the leading edge of the step and the stripe shall not overlap the leading edge of the step by not more than 1/2 inch (12.7 mm) down the vertical face of the step.
Exception: The minimum width of 1 inch (25 mm) shall not apply to outlining stripes listed in accordance with UL 1994.

Related Code Sections

1025.2.1 Means of Egress, Steps
A solid and continuous stripe shall be applied to the horizontal leading edge of each step and shall extend for the full length of the step ...
1025.2.1 Means of Egress, Steps
A solid and continuous stripe shall be applied to the horizontal leading edge of each step and shall extend for the full length of the step ...
1031.5.2.2 Means of Egress, Steps
Steps shall have an inside width of not less than 12 inches (305 mm), shall have treads greater than 5 inches (127 mm) in depth and a riser height ...
3202.2.1 Encroachments Into the Public Right-of-Way, Steps
Steps shall not project more than 12 inches (305 mm) and shall be guarded by approved devices not less than 3 feet (914 mm) in height, or shall ...
3202.2.1 Encroachments Into the Public Right-of-Way, Steps
Steps shall not project more than 12 inches (305 mm) and shall be guarded by approved devices not less than 3 feet (914 mm) in height, or shall ...