R602.11.2 Stepped Foundations in Seismic Design Categories D0, D1 and D2
JUMP TO FULL CODE CHAPTER
In all buildings located in Seismic Design Categories D0, D1 or D2, where the height of a required braced wall line that extends from foundation to floor above varies more than 4 feet (1219 mm), the braced wall line shall be constructed in accordance with the following:
FIGURE R602.11.2
STEPPED FOUNDATION CONSTRUCTION
- Where the lowest floor framing rests directly on a sill bolted to a foundation not less than 8 feet (2440 mm) in length along a line of bracing, the line shall be considered as braced. The double plate of the cripple stud wall beyond the segment of footing that extends to the lowest framed floor shall be spliced by extending the upper top plate a minimum of 4 feet (1219 mm) along the foundation. Anchor bolts shall be located a maximum of 1 foot and 3 feet (305 and 914 mm) from the step in the foundation. See Figure R602.11.2.
- Where cripple walls occur between the top of the foundation and the lowest floor framing, the bracing requirements of Sections R602.10.9 and R602.10.9.1 shall apply.
- Where only the bottom of the foundation is stepped and the lowest floor framing rests directly on a sill bolted to the foundations, the requirements of Sections R403.1.6 and R602.11.1 shall apply.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm.
Note: Where footing Section "A" is less than 8 feet long in a 25-foot-long wall, install bracing at cripple stud wall.
Note: Where footing Section "A" is less than 8 feet long in a 25-foot-long wall, install bracing at cripple stud wall.
STEPPED FOUNDATION CONSTRUCTION
Related Code Sections
R602.11.2 Wall Construction, Stepped Foundations in Seismic Design Categories D0, D1 and D2
In all buildings located in Seismic Design Categories D 0 , D 1 or D 2 , where the height of a required braced wall line that extends from ...
Residential Code 2015 of Pennsylvania > 6 Wall Construction > R602 Wood Wall Framing > R602.11 Wall Anchorage > R602.11.2 Stepped Foundations in Seismic Design Categories D0, D1 and D2
R602.11.2 Wall Construction, Stepped Foundations in Seismic Design Categories D0, D1 and D2
In all buildings located in Seismic Design Categories D 0 , D 1 or D 2 , where the height of a required braced wall line that extends from ...
Residential Code 2009 of Pennsylvania > 6 Wall Construction > R602 Wood Wall Framing > R602.11 Wall Anchorage > R602.11.2 Stepped Foundations in Seismic Design Categories D0, D1 and D2
R404.1.4 Foundations, Seismic Design Category D0, D1 or D2
In buildings assigned to Seismic Design Category D 0 , D 1 or D 2 , as established in Table R301.2(1), masonry foundation walls shall comply ...
Residential Code 2015 of Pennsylvania > 4 Foundations > R404 Foundation and Retaining Walls > R404.1 Concrete and Masonry Foundation Walls > R404.1.4 Seismic Design Category D0, D1 or D2
R404.1.4 Foundations, Seismic Design Category D0, D1 or D2
In addition to the requirements of Table R404.1.1(1) plain masonry foundation walls in buildings assigned to Seismic Design Category D 0 , D 1 or D ...
Residential Code 2009 of Pennsylvania > 4 Foundations > R404 Foundation and Retaining Walls > R404.1 Concrete and Masonry Foundation Walls > R404.1.4 Seismic Design Category D0, D1 or D2
R301.2.2.3 Building Planning, Seismic Design Categories D0, D1 and D2
Structures assigned to Seismic Design Categories D 0 , D 1 and D 2 shall conform to the requirements for Seismic Design Category C ...
Residential Code 2009 of Pennsylvania > 3 Building Planning > R301 Design Criteria > R301.2 Climatic and Geographic Design Criteria > R301.2.2 Seismic Provisions > R301.2.2.3 Seismic Design Categories D0, D1 and D2