• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R608.5.2 Steel Reinforcement and Anchor Bolts

Los Angeles Residential Code > 6 Wall Construction > R608 Exterior Concrete Wall Construction > R608.5 Materials > R608.5.2 Steel Reinforcement and Anchor Bolts
JUMP TO FULL CODE CHAPTER

R608.5.2.1 Steel Reinforcement

Steel reinforcement shall comply with ASTM A615, ASTM A706, or ASTM A996. ASTM A996 bars produced from rail steel shall be Type R.

R608.5.2.2 Anchor Bolts

Anchor bolts for use with connection details in accordance with Figures R608.9(1) through R608.9(12) shall be bolts with heads complying with ASTM A307 or ASTM F1554. ASTM A307 bolts shall be Grade A with heads. ASTM F1554 bolts shall be Grade 36 minimum. Instead of bolts with heads, it is permissible to use rods with threads on both ends fabricated from steel complying with ASTM A36. The threaded end of the rod to be embedded in the concrete shall be provided with a hex or square nut.

R608.5.2.3 Sheet Steel Angles and Tension Tie Straps

Angles and tension tie straps for use with connection details in accordance with Figures R608.9(1) through R608.9(12) shall be fabricated from sheet steel complying with ASTM A653 SS, ASTM A792 SS, or ASTM A875 SS. The steel shall be minimum Grade 33 unless a higher grade is required by the applicable figure.

Related Code Sections


R608.5.2 Wall Construction, Steel Reinforcement and Anchor Bolts
Steel reinforcement shall comply with ASTM A615, ASTM A706, or ASTM A996. ASTM A996 bars produced from rail steel shall be Type R ...
Los Angeles Residential Code > 6 Wall Construction > R608 Exterior Concrete Wall Construction > R608.5 Materials > R608.5.2 Steel Reinforcement and Anchor Bolts
R608.5.2 Wall Construction, Steel Reinforcement and Anchor Bolts
Steel reinforcement shall comply with ASTM A615, ASTM A706, or ASTM A996. ASTM A996 bars produced from rail steel shall be Type R ...
Los Angeles Residential Code > 6 Wall Construction > R608 Exterior Concrete Wall Construction > R608.5 Materials > R608.5.2 Steel Reinforcement and Anchor Bolts
R608.5.2.3 Wall Construction, Sheet Steel Angles and Tension Tie Straps
steel complying with ASTM A653 SS, ASTM A792 SS, or ASTM A875 SS. The steel shall be minimum Grade 33 unless a higher grade is required ...
Los Angeles Residential Code > 6 Wall Construction > R608 Exterior Concrete Wall Construction > R608.5 Materials > R608.5.2 Steel Reinforcement and Anchor Bolts > R608.5.2.3 Sheet Steel Angles and Tension Tie Straps
Section 1901 Concrete, General
Anchoring to concrete shall be in accordance with ACI 318 as amended in Section 1905, and applies to cast-in (headed bolts, headed studs and hooked J ...
Los Angeles Building Code > 19 Concrete > 1901 General
2204.3 Steel, Anchor Rods
Anchor rods shall be set in accordance with the approved construction documents. The protrusion of the threaded ends through the connected material ...
Los Angeles Building Code > 22 Steel > 2204 Connections > 2204.3 Anchor Rods
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE