316.6 Steel Nail Plates
JUMP TO FULL CODE CHAPTER
Plastic piping or tubing, copper or copper alloy piping or tubing, and ducts penetrating framing members to within 1 inch (25.4 mm) of the exposed framing shall be protected by steel nail plates not less than No. 18 gauge (0.0478 inches) (1.2141 mm) in thickness. The steel nail plate shall extend along the framing member not less than 11/2 inches (38 mm) beyond the outside diameter of the pipe or tubing.
Exception: See Section 1310.3.3.
Related Code Sections
312.9 General Regulations, Steel Nail Plates
nail plates not less than No. 18 gauge (0.0478 inches) (1.2 mm) in thickness. The steel nail plate shall extend along the framing member not less than ...
Uniform Plumbing Code 2018 of Nevada > 3 General Regulations > 312.0 Protection of Piping, Materials, and Structures > 312.9 Steel Nail Plates
316.6 General Regulations, Steel Nail Plates
framing shall be protected by steel nail plates not less than No. 18 gauge (0.0478 inches) (1.2141 mm) in thickness. The steel nail plate shall extend ...
Uniform Mechanical Code 2018 of Nevada > 3 General Regulations > 316.0 Protection of Piping, Tubing, Materials, and Structures > 316.6 Steel Nail Plates
R602.3.2 Wall Construction, Top Plate
plate or equivalent (6) 8d box (2 1 / 2 " × 0.113") nails 3" × 12" × 0.036" galvanized steel plate or equivalent (12) 8d box (2 1 / 2 ...
Residential Code 2018 of Nevada > 6 Wall Construction > R602 Wood Wall Framing > R602.3 Design and Construction > R602.3.2 Top Plate
(A) Wiring Methods and Materials, Cables and Raceways Through Wood Members
this distance cannot be maintained, the cable or raceway shall be protected from penetration by screws or nails by a steel plate(s) or bushing(s), at least ...
National Electrical Code 2017 of Nevada > 3 Wiring Methods and Materials > 300 General Requirements for Wiring Methods and Materials > 300.4 Protection Against Physical Damage > (A) Cables and Raceways Through Wood Members
R603.3.1 Wall Construction, Wall to Foundation or Floor Connection
spaced at 4' o.c., with 4-No. 8 screws and 4-10d or 6-8d common nails
Steel plate spaced at 4' o.c., with 4-No. 8 screws and 4-10d or 6 ...
Residential Code 2012 of Nevada > 6 Wall Construction > R603 Steel Wall Framing > R603.3 Wall Construction > R603.3.1 Wall to Foundation or Floor Connection