UpCodes logo
Jump To Full Code Chapter
All obligations of this section commence on the effective date except as follows:
1910.1027(p)(2)(i) Exposure Monitoring
Except for small businesses [nineteen (19) or fewer employees], initial monitoring required by paragraph (d)(2) of this section shall be completed as soon as possible and in any event no later than 60 days after the effective date of this standard. For small businesses, initial monitoring required by paragraph (d)(2) of this section shall be completed as soon as possible and in any event no later than 120 days after the effective date of this standard.
1910.1027(p)(2)(iii) Respiratory Protection
Except for small businesses, defined under paragraph (p)(2)(i) of this section, respiratory protection required by paragraph (g) of this section shall be provided as soon as possible and in any event no later than 90 days after the effective date of this section. For small businesses, respiratory protection required by paragraph (g) of this section shall be provided as soon as possible and in any event no later than 150 days after the effective date of this section.
1910.1027(p)(2)(iv) Compliance Program
Written compliance programs required by paragraph (f)(2) of this section shall be completed and available for inspection and copying as soon as possible and in any event no later than 1 year after the effective date of this section.
1910.1027(p)(2)(v) Methods of Compliance
The engineering controls required by paragraph (f)(1) of this section shall be implemented as soon as possible and in any event no later than two (2) years after the effective date of this section. Work practice controls shall be implemented as soon as possible. Work practice controls that are directly related to engineering controls to be implemented in accordance with the compliance plan shall be implemented as soon as possible after such engineering controls are implemented.
1910.1027(p)(2)(vi) Hygiene and Lunchroom Facilities
1910.1027(p)(2)(vi)(A)
Handwashing facilities, permanent or temporary, shall be provided in accordance with 29 CFR 1910.141(d)(1) and (2) as soon as possible and in any event no later than 60 days after the effective date of this section.
1910.1027(p)(2)(vi)(B)
Change rooms, showers, and lunchroom facilities shall be completed as soon as possible and in any event no later than 1 year after the effective date of this section.
1910.1027(p)(2)(vii) Employee Information and Training
Except for small businesses, defined under paragraph (p)(2)(i) above, employee information and training required by paragraph (m)(4) of this standard shall be provided as soon as possible and in any event no later than 90 days after the effective date of this standard. For small businesses, employee information and training required by paragraph (m)(4) of this standard shall be provided as soon as possible and in any event no later than 180 days after the effective date of this standard.
1910.1027(p)(2)(viii) Medical Surveillance
Except for small businesses, defined under paragraph (p)(2)(i) above, initial medical examinations required by paragraph (l) of this standard shall be provided as soon as possible and in any event no later than 90 days after the effective date of this standard. For small businesses, initial medical examinations required by paragraph (l) of this standard shall be provided as soon as possible and in any event no later than 180 days after the effective date of this standard.
1910.1027(p)(2)(ii) Regulated Areas
Except for small business, defined under paragraph (p)(2)(i) above, regulated areas required to be established by paragraph (e) of this section shall be set up as soon as possible after the results of exposure monitoring are known and in any event no later than 90 days after the effective date of this section. For small businesses, regulated areas required to be established by paragraph (e) of this section shall be set up as soon as possible after the results of exposure monitoring are known and in any event no later than 150 days after the effective date of this section.

Related Code Sections

1910.1027(p)(2) Toxic and Hazardous Substances, Start-Up Dates
the effective date of this section. For small businesses, regulated areas required to be established by paragraph (e) of this section shall be set up ...
1910.1027(p)(2)(viii) Toxic and Hazardous Substances, Medical Surveillance
be provided as soon as possible and in any event no later than 90 days after the effective date of this standard. For small businesses, initial medical ...