1701.2 Standards, Publications, Practices, and Guides
JUMP TO FULL CODE CHAPTER
The standards, publications, practices, and guides listed in Table 1701.2 are not referenced in other sections of this code. The application of the referenced standards, publications, practices, and guides shall be as specified in Section 301.2.2. The promulgating agency acronyms are found at the end of the tables.
DOCUMENT NUMBER | DOCUMENT TITLE | APPLICATION |
---|---|---|
AH AM FWD-1-2016 | Food Waste Disposers | Appliances |
ASCE 25-2016 | Earthquake-Actuated Automatic Gas Shutoff Devices | Fuel Gas |
ASHRAE/IES 90.1-2016 | Energy Standard for Buildings Except Low-Rise Residential Buildings | Miscellaneous |
ASHRAE/IES 90.2-2018 | Energy-Efficient Design of Low-Rise Residential Buildings | Miscellaneous |
ASHRAE 188-2018 | Legionellosis: Risk Management for Building Water Systems | Risk Management |
ASHRAE Guideline 12-2000 | Minimizing the Risk of Legionellosis Associated with Building Water Systems | Risk Management |
ASME A13.1-2015 | Scheme for the Identification of Piping Systems | Piping |
ASME A112.4.3-1999 (R2015) | Plastic Fittings for Connecting Water Closets to the Sanitary Drainage System | Fittings |
ASME A112.19.10-2017 | Retrofit Dual Flush Devices for Water Closets | Fixtures |
ASME A112.21.3M-1985 (R2017) | Hydrants for Utility and Maintenance Use | Valves |
ASME B1.20.3-1976 (R2018) | Dryseal Pipe Threads (Inch) | Joints |
ASME B16.33-2012 (R2017) | Manually Operated Metallic Gas Valves for Use in Gas Piping Systems Up to 175 psi (Sizes NPS 1/2 through NPS 2) | Valves |
ASME B16.39-2014 | Malleable Iron Threaded Pipe Unions: Classes 150, 250 and 300 | Fittings |
ASME B16.40-2013 | Manually Operated Thermoplastic Gas Shutoffs and Valves in Gas Distribution Systems | Valves |
ASME B31.1-2018 | Power Piping | Piping |
ASME B36.19M-2018 | Stainless Steel Pipe | Piping, Ferrous |
ASME BPVC Section IV-2015 | Rules for Construction of Heating Boilers | Miscellaneous |
ASSE 1017-2009 | Temperature Actuated Mixing Valves for Hot Water Distribution Systems | Valves |
ASSE 1032-2004 (R2011) | Dual Check Valve Type Backflow Preventers for Carbonated Beverage Dispensers, Post Mix Type | Backflow Protection |
ASSE 1066-1997 | Individual Pressure Balancing In-Line Valves for Individual Fixture Fittings | Valves |
ASSE 1082-2018 | Water Heaters with Integral Temperature Control Devices for Hot Water Distribution Systems | Appliances |
ASTM A48/A48M-2003 (R2016) | Gray Iron Castings | Piping, Ferrous |
ASTM A126-2004 (R2014) | Gray Iron Castings for Valves, Flanges, and Pipe Fittings | Piping, Ferrous |
ASTM A377-2018 | Ductile Iron Pressure Pipe | Piping, Ferrous |
ASTM A479/A479M-2018 | Stainless Steel Bars and Shapes for Use in Boilers and Other Pressure Vessels | Piping, Ferrous |
ASTM A536-1984 (R2014) | Ductile Iron Castings | Piping, Ferrous |
ASTM A733-2016 | Welded and Seamless Carbon Steel and Austenitic Stainless Steel Pipe Nipples | Piping, Ferrous |
ASTM A1045-2010 (R2017) | Flexible Poly (Vinyl Chloride) (PVC) Gaskets used in Connection of Vitreous China Plumbing Fixtures to Sanitary Drainage Systems | Piping, Plastic |
ASTM B29-2014 | Refined Lead | Joints |
ASTM B370-2012 | Copper Sheet and Strip for Building Construction | Miscellaneous |
ASTM B687-1999 (R2016) | Brass, Copper, and Chromium-Plated Pipe Nipples | Piping, Copper Alloy |
ASTM C14-2015a | Nonreinforced Concrete Sewer, Storm Drain, and Culvert Pipe | Piping, Non-Metallic |
ASTM C412-2015 | Concrete Drain Tile | Piping, Non-Metallic |
ASTM C443-2012 (R2017) | Joints for Concrete Pipe and Manholes, Using Rubber Gaskets | Joints |
ASTM C444-2017 | Perforated Concrete Pipe | Piping, Non-Metallic |
ASTM C478-2018 | Circular Precast Reinforced Concrete Manhole Sections | Miscellaneous |
ASTM C1227-2013 | Precast Concrete Septic Tanks | DWV Components |
ASTM C1440-2017 | Thermoplastic Elastomeric (TPE) Gasket Materials for Drain, Waste, and Vent (DWV), Sewer, Sanitary and Storm Plumbing Systems | Joints |
ASTM D1784-2011 | Rigid Poly (Vinyl Chloride) (PVC) Compounds and Chlorinated Poly (Vinyl Chloride) (CPVC) Compounds | Piping, Plastic |
ASTM D2321-2018 | Underground Installation of Thermoplastic Pipe for Sewers and Other Gravity-Flow Applications | Piping, Plastic |
ASTM D2517-2018 | Reinforced Epoxy Resin Gas Pressure Pipe and Fittings | Piping, Plastic |
ASTM D2657-2007 (R2015) | Heat Fusion Joining of Polyolefin Pipe and Fittings | Joints |
ASTM D2774-2012 | Underground Installation of Thermoplastic Pressure Piping | Piping, Plastic |
ASTM D2855-2015 | Two-Step (Primer and Solvent Cement) Method of Joining Poly (Vinyl Chloride) (PVC) or Chlorinated Poly (Vinyl Chloride) (CPVC) Pipe and Piping Components with Tapered Sockets | Joints |
ASTM D3122-2015 | Solvent Cement for Styrene-Rubber (SR) Plastic Pipe and Fittings | Joints |
ASTM D3311-2017 | Drain, Waste, and Vent (DWV) Plastic Fittings Patterns | Fittings |
ASTM F402-2018 | Safe Handling of Solvent Cements, Primers, and Cleaners Used for Joining Thermoplastic Pipe and Fittings | Joints |
ASTM F480-2014 | Thermoplastic Well Casing Pipe and Couplings Made in Standard Dimension Ratios (SDR), SCH 40 and SCH 80 | Piping, Plastic |
ASTM F810-2012 (R2018) | Smoothwall Polyethylene (PE) Pipe for Use in Drainage and Waste Disposal Absorption Fields | Piping, Plastic |
ASTM F949-2015 | Poly (Vinyl Chloride) (PVC) Corrugated Sewer Pipe with a Smooth Interior and Fittings | Piping, Plastic |
ASTM F1476-2007 (R2013) | Performance of Gasketed Mechanical Couplings for Use in Piping Applications | Joints |
ASTM F1499-2017 | Coextruded Composite Drain, Waste, and Vent Pipe (DWV) | Piping, Plastic |
ASTM F1743-2017 | Rehabilitation of Existing Pipelines and Conduits by Pulled-in-Place Installation of Cured-in-Place Thermosetting Resin Pipe (CIPP) | Piping, Plastic |
ASTM F1924-2012 | Plastic Mechanical Fittings for Use on Outside Diameter Controlled Polyethylene Gas Distribution Pipe and Tubing | Fittings |
ASTM F1948-2015 | Metallic Mechanical Fittings for Use on Outside Diameter Controlled Thermoplastic Gas Distribution Pipe and Tubing | Fittings |
ASTM F2165-2013 | Flexible Pre-Insulated Piping | Piping, Plastic |
ASTM F2206-2014 | Fabricated Fittings of Butt-Fused Polyethylene (PE) | DWV Components |
ASTM F2306/F2306M-2018 | 12 to 60 in. [300 to 1500 mm] Annular Corrugated Profile-Wall Polyethylene (PE) Pipe and Fittings for Gravity-Flow Storm Sewer and Subsurface Drainage Applications | Piping, Plastic |
AWS B2.4-2012 | Welding Procedure and Performance Qualification for Thermoplastics | Joints, Certification |
AWWA C203-2015 | Coal-Tar Protective Coatings and Linings for Steel Water Pipe | Miscellaneous |
AWWA C213-2015 | Fusion-Bonded Epoxy Coatings and Linings for Steel Water Pipe and Fittings | Miscellaneous |
AWWA C215-2016 | Extruded Polyolefin Coatings for Steel Water Pipe | Miscellaneous |
AWWA C606-2015 | Grooved and Shouldered Joints | Joints |
CGA C-9-2013 | Standard Color Marking of Compressed Gas Containers for Medical Use | Miscellaneous |
CGA S-1.3-2008 | Pressure Relief Device Standards-Part 3-Stationary Storage Containers for Compressed Gases | Fuel Gas |
CGA V-1-2013 | Compressed Gas Cylinder Valve Outlet and Inlet Connections | Valves |
CSA A257-2014 | Concrete Pipe and Manhole Sections | Piping |
CSA B55.2-2015 | Drain Water Heat Recovery Units | Miscellaneous |
CSA B64.7-2011 (R2016) | Laboratory Faucet Vacuum Breakers (LFVB) | Backflow Protection |
CSA B66-2016 | Design, Material, and Manufacturing Requirements for Prefabricated Septic Tanks and Sewage Holding Tanks | DWV Components |
CSA B 128.1-2006/B128.2-2006 (R2016) | Design and Installation of Non-Potable Water Systems/Maintenance and Field Testing of Non-Potable Water Systems | Miscellaneous |
CSA B242-2005 (R2016) | Groove- and Shoulder-Type Mechanical Pipe Couplings | Fittings |
CSA B356-2010 (R2015) | Water Pressure Reducing Valves for Domestic Water Supply Systems | Valves |
CSA G401-2014 | Corrugated Steel Pipe Products | Piping, Ferrous |
CSA Z21.12b-1994 (R2015) | Draft Hoods | Fuel Gas, Appliances |
CSA Z21.13-2017 | Gas-Fired Low-Pressure Steam and Hot Water Boilers (same as CSA 4.9) | Fuel Gas, Appliances |
CSA Z21.15b-2013 (R2014) | Manually Operated Gas Valves for Appliances, Appliance Connector Valves, and Hose End Valves (same as CSA 9.1b) | Fuel Gas |
CSA Z21.81a-2007 (R2015) | Cylinder Connection Devices (same as CSA 6.25a) | Fuel Gas |
CSA Z21.86-2016 | Vented Gas-Fired Space Heating Appliances (same as CSA 2.32) | Fuel Gas, Appliances |
CSA Z83.11-2016 | Gas Food Service Equipment (same as CSA 1.8) | Fuel Gas, Appliances |
CSA Z317.1-2016 | Special Requirements for Plumbing Installations in Health Care Facilities | Miscellaneous |
Energy Star-2012 (version 2.0) | Program Requirements Product Specification for Commercial Dishwashers | Appliances |
Energy Star-2018 (version 8.0) | Program Requirements Product specification for Clothes Washers (effective February 5, 2018) | Appliances |
Energy Star-2016 (version 6.0) | Program Requirements for Residential Dishwashers | Appliances |
EPA/600/R-12/618-2012 | Guidelines for Water Reuse | Miscellaneous |
EPA WaterSense-2007 | High-Efficiency Lavatory Faucet Specification | Fixtures |
EPA WaterSense-2009 | Specification for Flushing Urinals | Fixtures |
EPA WaterSense-2014 | Specification for Tank-Type Toilets | Fixtures |
IAPMO IGC 67-2014e1 | Specialized ABS and PVC DWV Fittings | DWV Components |
IAPMO IGC 109-2017 | Water Distribution Manifolds | Valves |
IAPMO IGC 183-2016 | Oil/Water Separators and Coalescing Plate Separators | DWV Components |
IAPMO IGC 193-2010 | Safety Plates, Plate Straps, Notched Plates and Safety Collars | Miscellaneous |
IAPMO IGC 244-2015a | Tub and Shower Flow-Reduction Systems | Valves |
IAPMO IGC 226-2006a | Drinking Water Fountains With or Without Chiller or Heater | Fixtures |
IAPMO IGC 267-2015e1 | Hydrants Without Integral Backflow Preventers | Valves |
IAPMO IGC 276-2011 | Bundled Expanded Polystyrene Synthetic Aggregate Units | DWV Components |
IAPMO IGC 315-2016 | Water Manifold Systems | Fittings |
IAPMO IGC 327-2016 | Flexible Metallic Expansion Joints for Pressure Systems | Joints |
IAPMO IGC 330-2017 | Recirculating Shower Systems | Fixtures |
IAPMO IGC 332-2017a | Hydronic Radiators | Miscellaneous |
IAPMO PS 1-2007 | Tank Risers | DWV Components |
IAPMO PS 23-2006a | Dishwasher Drain Airgaps | Backflow Protection |
IAPMO PS 25-2002 | Metallic Fittings for Joining Polyethylene Pipe for Water Service and Yard Piping | Joints |
IAPMO PS 34-2003 | Encasement Sleeve for Potable Water Pipe and Tubing | Piping |
IAPMO PS 36-2014e1 | Lead-Free Sealing Compounds for Threaded Joints | Joints |
IAPMO PS 37-1990 | Black Plastic PVC or PE Pressure-Sensitive Corrosion Preventive Tape | Miscellaneous |
IAPMO PS 42-2013e1 | Pipe Alignment and Secondary Support Systems | Miscellaneous |
IAPMO PS 50-2010 | Flush Valves with Dual Flush Device for Water Closets or Water Closet Tank with an Integral Flush Valves with a Dual Flush Device | Fixtures |
IAPMO PS 51-2016 | Expansion Joints and Flexible Expansion Joints for DWV Piping Systems | Joints |
IAPMO PS 52-2009e1 | Pump/Dose, Sumps and Sewage Ejector Tanks with or without a Pump | DWV Components |
IAPMO PS 53-2016a | Grooved Mechanical Pipe Couplings and Grooved Fittings | Joints |
IAPMO PS 54-2015 | Metallic and Plastic Utility Boxes | Miscellaneous |
IAPMO PS 57-2002 | PVC Hydraulically Actuated Diaphragm Type Water Control Valves | Valves |
IAPMO PS 63-2014 | Plastic Leaching Chambers | DWV Components |
IAPMO PS 64-2012ae1 | Roof Pipe Flashings | Miscellaneous |
IAPMO PS 66-2015 | Dielectric Fittings | Fittings |
IAPMO PS 67-2010 | Early-Closure Replacement Flappers or Early-Closure Replacement Flapper with Mechanical Assemblies | Fixtures |
IAPMO PS 69-2006 | Bathwaste and Overflow Assemblies with Tub Filler Spout | DWV Components |
IAPMO PS 72-2007e1 | Valves with Atmospheric Vacuum Breakers | Valves |
IAPMO PS 73-2015 | Dental Liquid-Ring Vacuum Pumps | Miscellaneous |
IAPMO PS 76-2012a | Trap Primers for Fill Valves and Flushometer Valves | DWV Components |
IAPMO PS 79-2005 | Multiport Electronic Trap Primer | DWV Components |
IAPMO PS 80-2008 | Clarifiers | DWV Components |
IAPMO PS 81-2006 | Precast Concrete Seepage Pit Liners and Covers | DWV Components |
IAPMO PS 82-1995 | Fiberglass (Glass Fiber Reinforced Thermosetting Resin) Fittings | Fittings |
IAPMO PS 85-1995 | Tools for Mechanically Formed Tee Connections in Copper Tubing | Miscellaneous |
IAPMO PS 86-1995 | Rainwater Diverter Valve for Non-Roofed Area Slabs | DWV Components |
IAPMO PS 89-1995 | Soaking and Hydrotherapy (Whirlpool) Bathtubs with Hydraulic Seatlift | Fixtures |
IAPMO PS 90-2014 | Elastomeric Test Caps, Cleanout Caps, and Combination Test Caps/Shielded Couplings | DWV Components |
IAPMO PS 91-2005a | Plastic Stabilizers for Use with Plastic Closet Bends | DWV Components |
IAPMO PS 92-2013e1 | Heat Exchangers and Indirect Water Heaters | Miscellaneous |
IAPMO PS 94-2012e1 | Insulated Protectors for P-Traps, Supply Stops and Risers | Miscellaneous |
IAPMO PS 95-2018e1 | Pipe Support Hangers and Hooks | DWV Components |
IAPMO PS 98-1996 | Prefabricated Fiberglass Church Baptisteries | Fixtures |
IAPMO PS 100-1996 | Porous Filter Protector for Sub-Drain Weep Holes | DWV Components |
IAPMO PS 101-1997 | Suction Relief Valves | Valves |
IAPMO PS 104-1997 | Pressure Relief Connection for Dispensing Equipment | Valves |
IAPMO PS 105-1997 | Polyethylene Distribution Boxes | DWV Components |
IAPMO PS 106-2015e1 | Tileable Shower Receptors and Shower Kits | Fixtures |
IAPMO PS 110-2006a | PVC Cold Water Compression Fittings | Fittings |
IAPMO PS 111-1999 | PVC Cold Water Gripper Fittings | Fittings |
IAPMO PS 112-1999 | PVC Plastic Valves for Cold Water Distribution Systems Outside a Building and CPVC Plastic Valves for Hot and Cold Water Distribution Systems | Valves |
IAPMO PS 113-2010 | Hydraulically Powered Household Food Waste Disposers | Appliances |
IAPMO PS 114-1999e1 | Remote Floor Box Industrial Water Supply, Air Supply, Drainage | Miscellaneous |
IAPMO PS 115-2007 | Hot Water On-Demand or Automatic Activated Hot Water Pumping Systems | Miscellaneous |
IAPMO PS 116-1999 | Hot Water Circulating Devices Which Do Not Use a Pump | Miscellaneous |
IAPMO PS 119-2012ae3 | Water-Powered Sump Pumps | Miscellaneous |
IAPMO Z124.7-2013 | Prefabricated Plastic Spa Shells | Fixtures, Swimming Pools, Spas, and Hot Tubs |
IAPMO Z124.8-2013e2 | Plastic Liners for Bathtubs and Shower Receptors | Fixtures |
IAPMO Z1000-2013 | Prefabricated Septic Tanks | DWV Components |
MSS SP-25-2018 | Standard Marking System for Valves, Fittings, Flanges, and Unions | Miscellaneous |
MSS SP-42-2013 | Corrosion-Resistant Gate, Globe, Angle, and Check Valves with Flanged and Butt Weld Ends (Classes 150, 300, & 600) | Piping, Ferrous |
MSS SP-44-2016 (R2017) | Steel Pipeline Flanges | Fittings |
MSS SP-83-2018 | Class 3000 and 6000 Pipe Unions, Socket Welding and Threaded (Carbon Steel, Alloy Steel, Stainless Steels, and Nickel Alloys) | Joints |
MSS SP-104-2018 | Wrought Copper, Solder-Joint Pressure Fittings | Fittings |
MSS SP-106-2012 | Cast Copper Alloy Flanges and Flanged Fittings: Class 125, 150, and 300 | Fittings |
MSS SP-109-2018 | Weld-Fabricated, Copper Solder-Joint Pressure Fittings | Fittings |
MSS SP-123-2013 | Non-Ferrous Threaded and Solder-Joint Unions for Use with Copper Water Tube | Joints |
NFPA 13R-2019 | Installation of Sprinkler Systems in Low-Rise Residential Occupancies | Miscellaneous |
NFPA 80-2019 | Fire Doors and Other Opening Protectives | Miscellaneous |
NFPA 501A-2017 | Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities | Miscellaneous |
NFPA 1981-2013 | Open-Circuit Self-Contained Breathing Apparatus (SCBA) for Emergency Services | Miscellaneous |
NFPA 1989-2019 | Breathing Air Quality for Emergency Services Respiratory Protection | Miscellaneous |
NFPA 5000-2018 | Building Construction and Safety Code | Miscellaneous |
NSF 2-2018 | Food Equipment | Appliances |
NSF 4-2016 | Commercial Cooking, Rethermalization, and Powered Hot Food Holding and Transportation Equipment | Appliances |
NSF 5-2016 | Water Heaters, Hot Water Supply Boilers, and Heat Recovery Equipment | Appliances |
NSF 12-2018 | Automatic Ice Making Equipment | Appliances |
NSF 18-2016 | Manual Food and Beverage Dispensing Equipment | Appliances |
NSF 29-2017 | Detergent and Chemical Feeders for Commercial Spray-Type Dishwashing Machines | Appliances |
NSF 40-2018 | Residential Wastewater Treatment Systems | DWV Components |
NSF 41-2018 | Non-Liquid Saturated Treatment Systems | DWV Components |
NSF 46-2018 | Evaluation of Components and Devices Used in Wastewater Treatment Systems | DWV Components |
NSF 169-2016 | Special Purpose Food Equipment and Devices | Appliances |
PSAI Z4.1-2016 | For Sanitation — In Places of Employment: Minimum Requirements | Miscellaneous |
SAE J512-1997 | Automotive Tube Fittings | Fittings |
SAE J1670-2008 | Type "F" Clamps for Plumbing Applications | Joints |
TCNA A118.10-2014 | Load Bearing, Bonded, Waterproof Membranes for Thin-Set Ceramic Tile and Dimension Stone Installation | Miscellaneous |
Title 49, Code of Federal Regulations, Part 192 | Transportation of Natural and Other Gas by Pipeline: Minimum Federal Standards | Miscellaneous |
UL 70-2001 | Septic Tanks, Bituminous-Coated Metal | DWV Components |
UL 80-2007 | Steel Tanks for Oil-Burner Fuels and Other Combustible Liquids (with revisions through January 16, 2014) | Fuel Gas |
UL 144-2012 | LP-Gas Regulators (with revisions through November 5, 2014) | Fuel Gas |
UL 252-2017 | Compressed Gas Regulators (with revisions through August 10, 2018) | Fuel Gas |
UL 296-2017 | Oil Burners (with revisions through November 29,2017) | Fuel Gas, Appliances |
UL 404-2010 | Gauges, Indicating Pressure, for Compressed Gas Service (with revisions through February 11, 2015) | Fuel Gas |
UL 429-2013 | Electrically Operated Valves | Valves |
UL 536-2014 | Flexible Metallic Hose | Fuel Gas |
UL 563-2009 | Ice Makers (with revisions through August 30, 2018) | Appliances |
UL 569-2013 | Pigtails and Flexible Hose Connectors for LP-Gas (with revisions through July 28, 2017) | Fuel Gas |
UL 726-1995 | Oil-Fired Boiler Assemblies (with revisions through October 9, 2013) | Fuel Gas, Appliances |
UL 1206-2003 | Electric Commercial Clothes-Washing Equipment (with revisions through January 7, 2019) | Appliances |
UL 1331-2005 | Station Inlets and Outlets (with revisions through May 12, 2017) | Medical Gas |
UL 1795-2016 | Hydromassage Bathtubs (with revisions through December 8, 2017) | Fixtures |
UL 1951-2011 | Electric Plumbing Accessories (with revisions through August 25, 2017) | Miscellaneous |
UL 2157-2018 | Electric Clothes Washing Machines and Extractors | Appliances |
WQA S-300-2000 | Point-of-Use Low-Pressure Reverse Osmosis Drinking Water Systems | Appliances |
ABBREVIATIONS IN TABLE 1701.1 AND TABLE 1701.2
AHAM | Association of Home Appliance Manufacturers, 1111 19th Street, NW, Suite 402, Washington, DC 20036. |
ANSI | American National Standards Institute, Inc., 25 W. 43rd Street, 4th Floor, New York, NY 10036. |
ARCSA | American Rainwater Catchment Systems Association, 6101 Long Prairie Road, Suite 744, PMB 251, Flower Mound, TX 75028. |
ASCE | American Society of Civil Engineers, 1801 Alexander Bell Drive, Reston, VA 20191-4400. |
ASHRAE | American Society of Heating, Refrigerating, and Air Conditioning Engineers, Inc., 1791 Tullie Circle, NE, Atlanta, GA 30329-2305. |
ASME | American Society of Mechanical Engineering, Two Park Avenue, New York, NY 10016-5990. |
ASPE | American Society of Plumbing Engineers, 6400 Shafer Court, Suite 350, Rosemont, IL 60018. |
ASSE | American Society of Sanitary Engineering, 18927 Hickory Creek Drive, Suite 220, Mokena, IL 60448. |
ASTM | ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959. |
AWS | American Welding Society, 8669 NW 36 Street, #130 Miami, FL 33166-6672. |
AWWA | American Water Works Association, 6666 W. Quincy Avenue, Denver, CO 80235. |
CFR | Code of Federal Regulations, U.S Government Publishing Office, 723 North Capitol Street, N.W. Washington, DC 20401-001 |
CGA | Compressed Gas Association, 14501 George Carter Way, Suite 103, Chantilly, VA 20151. |
CISPI | Cast-Iron Soil Pipe Institute, 2401 Fieldcrest Drive, Mundelein, IL 60060. |
CSA | Canadian Standards Association, 178 Rexdale Boulevard, Toronto, Ontario, Canada, M9W 1R3. |
DOE | U.S. Department of Energy, Forrestal Building, 1000 Independence Avenue, SW, Washington, DC 20585. |
e1 | An editorial change since the last revision or reapproval. |
ENERGY STAR | 1200 Pennsylvania Avenue, N.W., Washington, D.C. 20460. |
EPA WATERSENSE | U.S. Environmental Protection Agency, Office of Wastewater Management (4204M), 1200 Pennsylvania Avenue, N.W., Washington, D.C. 20460. |
IAPMO | International Association of Plumbing and Mechanical Officials, 4755 E. Philadelphia Street, Ontario, CA 91761. |
ICC | International Code Council, 500 New Jersey Avenue, NW, 6th Floor, Washington, DC 20001. |
ISEA | International Safety Equipment Association, 1901 N. Moore Street, Suite 808, Arlington, VA 22209-1762. |
ISO | International Organization for Standardization, 1 ch. de la Voie-Creuse, Casa Postale 56, CH-1211 Geneva 20, Switzerland. |
MSS | Manufacturers Standardization Society of the Valve and Fittings Industry, 127 Park Street, NE, Vienna, VA 22180. |
NFPA | National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169-7471. |
NSF | NSF International, 789 N. Dixboro Road, Ann Arbor, MI 48105. |
PDI | Plumbing and Drainage Institute, 800 Turnpike Street, Suite 300, North Andover, MA 01845. |
PSAI | Portable Sanitation Association International, 2626 E. 82nd Street, Suite 175, Bloomington, MN 55425. |
SAE | Society of Automotive Engineers, 400 Commonwealth Drive, Warrendale, PA 15096. |
TCNA | Tile Council of North America, Inc. 100 Clemson Research Blvd., Anderson, SC 29625. |
UL | Underwriters Laboratories, Inc., 333 Pfingsten Road, Northbrook, IL 60062. |
WQA | Water Quality Association, 4151 Naperville Road, Lisle, IL 60532-3696. |
Related Code Sections
1701.2 Referenced Standards, Standards, Publications, Practices, and Guides
The standards, publications, practices, and guides listed in Table 1701.2 are not referenced in other sections of this code. The application ...
2021 Oregon Plumbing Specialty Code > 17 Referenced Standards > 1701.0 General > 1701.2 Standards, Publications, Practices, and Guides
301.2.2 General Regulations, Standards
standards, publications, practices, and guides that are not referenced in specific sections of this code appear in Table 1701.2. An IAPMO Installation ...
2021 Oregon Plumbing Specialty Code > 3 General Regulations > 301.0 General > 301.2 Minimum Standards > 301.2.2 Standards
3.2.6 Definitions, Standard
"standards" includes all NFPA Standards, including Codes, Standards, Recommended Practices, and Guides ...
Standard for the Installation of Sprinkler Systems 2016 of Portland > 3 Definitions > 3.2 NFPA Official Definitions > 3.2.6 Standard
480.1 Equipment for General Use, Scope
, Guide for the Ventilation and Thermal Management of Batteries for Stationary Applications UL. 1973, Standard for Batteries for Use in Stationary ...
2021 Oregon Electrical Specialty Code (OESC) > 4 Equipment for General Use > 480 Storage Batteries > 480.1 Scope
2.3.4 Referenced Publications, ASTM Publications
and Copper-Alloy Tube, 2010. ASTM B828, Standard Practice for Making Capillary Joints by Soldering of Copper and Copper Alloy Tube and Fittings, 2002 ...
Standard for the Installation of Sprinkler Systems 2016 of Portland > 2 Referenced Publications > 2.3 Other Publications > 2.3.4 ASTM Publications