• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

608.2.2 Standard Roll-In Type Shower Compartments

2010 ADA Standards > 6 Plumbing Elements and Facilities > 608 Shower Compartments > 608.2 Size and Clearances for Shower Compartments > 608.2.2 Standard Roll-In Type Shower Compartments
JUMP TO FULL CODE CHAPTER
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides and shall have a 60 inches (1525 mm) wide minimum entry on the face of the shower compartment.

608.2.2.1 Clearance

A 30 inch (760 mm) wide minimum by 60 inch (1525 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment.

EXCEPTION: A lavatory complying with 606 shall be permitted on one 30 inch (760 mm) wide minimum side of the clearance provided that it is not on the side of the clearance adjacent to the controls or, where provided, not on the side of the clearance adjacent to the shower seat.
Figure 608.2.2 Standard Roll-In Type Shower Compartment Size and Clearance
A plan view shows the shower compartment is 30 inches (760 mm) minimum by 60 inches (1525 mm) minimum with a 60 inch (1525 mm) wide entry on the face of the compartment.  A clear floor space 30 inches (760 mm) side is provided adjacent to the open face of the compartment.  A seat is shown on one end.  A lavatory is permitted within the clear floor space on the end opposite the seat.

Related Code Sections


608.5.2 Plumbing Elements and Facilities, Standard Roll-In Type Shower Compartments
In standard roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 ...
2010 ADA Standards > 6 Plumbing Elements and Facilities > 608 Shower Compartments > 608.5 Controls > 608.5.2 Standard Roll-In Type Shower Compartments
608.2 Plumbing Elements and Facilities, Size and Clearances for Shower Compartments
, not on the side of the clearance adjacent to the shower seat. Figure 608.2.2 Standard Roll-In Type Shower Compartment Size and Clearance ...
2010 ADA Standards > 6 Plumbing Elements and Facilities > 608 Shower Compartments > 608.2 Size and Clearances for Shower Compartments
608.3 Plumbing Elements and Facilities, Grab Bars
Where a seat is provided in standard roll-in type shower compartments, grab bars shall be provided on the back ...
2010 ADA Standards > 6 Plumbing Elements and Facilities > 608 Shower Compartments > 608.3 Grab Bars
610.3 Plumbing Elements and Facilities, Shower Compartment Seats
Where a seat is provided in a standard roll-in shower compartment, it shall be a folding type, shall be installed on the side wall adjacent ...
2010 ADA Standards > 6 Plumbing Elements and Facilities > 610 Seats > 610.3 Shower Compartment Seats
608.2.3 Plumbing Elements and Facilities, Alternate Roll-In Type Shower Compartments
Figure 608.2.3 Alternate Roll-In Type Shower Compartment Size and Clearance ...
2010 ADA Standards > 6 Plumbing Elements and Facilities > 608 Shower Compartments > 608.2 Size and Clearances for Shower Compartments > 608.2.3 Alternate Roll-In Type Shower Compartments
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING