• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

3310.1 Stairways Required

Building Code 2018 of Illinois > 33 Safeguards During Construction > 3310 Means of Egress > 3310.1 Stairways Required
JUMP TO FULL CODE CHAPTER
Where building construction exceeds 40 feet (12 192 mm) in height above the lowest level of fire department vehicle access, a temporary or permanent stairway shall be provided. As construction progresses, such stairway shall be extended to within one floor of the highest point of construction having secured decking or flooring.

Related Code Sections


1505.1 Construction Safeguards, Stairways Required
stairway shall be provided. As construction progresses, such stairway shall be extended to within one floor of the highest point of construction ...
Existing Building Code 2018 of Illinois > 15 Construction Safeguards > 1505 Means of Egress > 1505.1 Stairways Required
1505.1 Construction Safeguards, Stairways Required
stairway shall be provided. As construction progresses, such stairway shall be extended to within one floor of the highest point of construction ...
Existing Building Code 2021 of Illinois > 15 Construction Safeguards > 1505 Means of Egress > 1505.1 Stairways Required
3310.1 Safeguards During Construction, Stairways Required
stairway shall be provided. As construction progresses, such stairway shall be extended to within one floor of the highest point of construction ...
Building Code 2021 of Illinois > 33 Safeguards During Construction > 3310 Means of Egress > 3310.1 Stairways Required
3310.1 Safeguards During Construction, Stairways Required
stairway shall be provided. As construction progresses, such stairway shall be extended to within one floor of the highest point of construction ...
Building Code 2018 of Illinois > 33 Safeguards During Construction > 3310 Means of Egress > 3310.1 Stairways Required
802.2.3 Alterations—Level 2, Supplemental Stairway Enclosure Requirements
Where the work area on any floor exceeds 50 percent of that floor area, stairways that are part of the means of egress serving the work area ...
Existing Building Code 2018 of Illinois > 8 Alterations—Level 2 > 802 Building Elements and Materials > 802.2 Vertical Openings > 802.2.3 Supplemental Stairway Enclosure Requirements
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING